Wacker Neuson M1000 Operator's Manual page 36

Drive motor for modular internal vibrator hms
Hide thumbs Also See for M1000:
Table of Contents

Advertisement

10 Use and operation
Checking the GFCI for proper functioning
1. Turn off ON/OFF switch.
2. If required, connect a permitted extension cable to the power cable of the ma-
3. Insert the plug into the plug receptacle.
4. Press push butten 'Test' on GFCI. Inside the GFCI a leakage current will be
5. Press push button 'Reset' on GFCI or pull the plug out of the plug receptacle
The control lamps of the GFCI light up if the machine is correctly connected and
there are no leakage currents.
The control lamp of the GFCI does not light up if there is a malfunction or fault,
see chapter Malfunctions.
Note: When the ON/OFF switch is pressed, the HMS starts to run imme-dia-
tely at the connection. The Vibrator head can strike out and may injure per-
sons or be damaged.
chine.
Note: See chapter Technical data for the permitted lengths and cross-sec-
tion areas of extension cables.
simulated to test the switching device, the GFCI switches off and the indicator
light goes off.
and then plug back the plug into the plug receptacle.
36
100_0101_op_0008.fm

Advertisement

Table of Contents
loading

This manual is also suitable for:

M2000M3000

Table of Contents