Wacker Neuson M1000 Operator's Manual page 32

Drive motor for modular internal vibrator hms
Hide thumbs Also See for M1000:
Table of Contents

Advertisement

9 Mounting the HMS
Coupling the flexible shaft to the drive
1. Switch off the drive motor via the ON/OFF switch.
2. Pull the plug from the plug receptacle.
3. Set drive motor on the floor..
4. Pull the T-handle upwards.
5. Insert the coupling of the flexible shaft into the quick disconnect coupler of the
6. Release the T-handle.
7. Turn the flexible shaft until the quick disconnect coupler engages.
8. Control whether the quick disconnect coupler is completely engaged by pull-
Note: If the flexible shaft core is new, the drive motor must run approx.
Item
Designation
1
Flexible shaft
2
Coupling
drive motor and make sure it engages, so that the shaft core fully enters the
shaft core adapter on the drive motor.
ing on the flexible shaft.
5 minutes with the flexible shaft connected (if necessary with the vibrator
head as well).
32
100_0101_is_0001.fm

Advertisement

Table of Contents
loading

This manual is also suitable for:

M2000M3000

Table of Contents