Waldorf CH8300G Installation And Operation Manual

800 series chargrill
Hide thumbs Also See for CH8300G:

Advertisement

I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l
Chargrill
CH8300G
CHL8300G
CH8450G
CHL8450G
CH8600G
CHL8600G
CH8900G
CHL8900G
CH8120G
CHL8120G
CHB8300G
CHLB8300G
CHB8450G
CHLB8450G
CHB8600G
CHLB8600G
CHB8900G
CHLB8900G
CHB8120G
CHLB8120G
Date Purchased
Serial Number
Dealer
Service Provider
For use in GB, IE & DK
228592-38

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CH8300G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Waldorf CH8300G

  • Page 1 I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Chargrill CH8300G CHL8300G CH8450G CHL8450G CH8600G CHL8600G CH8900G CHL8900G CH8120G...
  • Page 2 MANUFACTURED BY Moffat Limited Rolleston 7675 New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888 (fax) +61 (03) 9518 3833 Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315...
  • Page 3: Table Of Contents

    Contents CH(L)8300G-(B) Gas Chargrill, 300mm wide - Bench Model Only. CH(L)8450G-(B) Gas Chargrill, 450mm wide. CH(L)8600G-(B) Gas Chargrill, 600mm wide. CH(L)8900G-(B) Gas Chargrill, 900mm wide. CH(L)8120G-(B) Gas Chargrill, 1200mm wide. Introduction ......................2 Specification ......................3 Model Numbers Covered in this Specification Gas Supply Requirements Dimensions ......................
  • Page 4: Introduction

    Introduction We are confident that you will be delighted with your WALDORF CHARGRILL, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Waldorf CHARGRILL, there are two important things you can do.
  • Page 5: Specification

    Male Male * - Measure burner operating pressure at the manifold test point with one burner for CH8300G and CH8450G models or two burners for other models operating at full setting. Operating pressure is ex-factory set and not to be adjusted, apart from when converting between gases, if required.
  • Page 6 Male Male * - Measure burner operating pressure at the manifold test point with one burner for CH8300G and CH8450G models or two burners for other models operating at full setting. Operating pressure is ex-factory set and not to be adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’...
  • Page 7: Dimensions

    Dimensions NOTE: The CH8300G are available in Bench Model (- B) Option Only. CH(L)8300G-B CH(L)8450G-B CH(L)8600G-B CH(L)8900G-B CH(L)8120G-B...
  • Page 8 Dimensions CH(L)8450G-LS CH(L)8600G-LS...
  • Page 9 Dimensions CH(L)8900G-LS CH(L)8120G-LS...
  • Page 10: Installation

    Waldorf Chargrills are designed to provide years of satisfactory service, and correct installation is essential to achieve the best performance, efficiency and trouble-free operation. This appliance must be installed in accordance with National Installation Codes and in addition, in accordance with relevant National / Local Codes covering gas and fire safety.
  • Page 11: Clearances

    200mm Rear 150mm Assembly Bench Models (CH8300G Models Only). Check all feet are securely fitted. Bench Models (CH4500G / CH8600G / CH8900G / CH8120G Models Only) Check all feet are securely fitted. Adjust feet to make the Chargrill steady and level.
  • Page 12: Fitting Adjustable Feet / Rear Rollers To Leg Stand Units

    Installation Fitting of Adjustable Feet / Rear Rollers to Leg Stand Units. Warning TO PREVENT EQUIPMENT DAMAGE AND RISK OF INJURY REMOVE ALL CHARGRILL CASTINGS BURNERS AND OTHER REMOVABLE ITEMS PRIOR TO FITTING THE LEG STAND Remove grates, griddle plates and radiants from chargrill.
  • Page 13: Gas Connection

    NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON. Waldorf Chargrills do not require an electrical connection, as they function on gas supply only. It is essential that gas supply is correct for chargrill to be installed and that adequate supply pressure and volume is available.
  • Page 14: Commissioning

    Installation Commissioning Before leaving new installation; a. Check the following functions in accordance with operating instructions specified in 'Operation' section of this manual.  Light the Pilot Burner.  Light the Main Burner.  Check Low Fire Burner Operation.  Check High Fire Burner Operation. b.
  • Page 15: Operation

    Operation Operation Guide Caution  This appliance is for professional use and is only to be used by qualified persons.  Only authorised service persons are to carry out installation, servicing or gas conversion operations.  Components having adjustments protected (e.g.
  • Page 16: Lighting Pilot Burners

    Operation Lighting Pilot Burners Warning 350°C HEN A SOLID GRIDDLE PLATE IS USED S SURFACE TEMPERATURE CAN REACH OVER WHEN THE APPLIANCE IS OPERATED AT FULL HEAT SETTING NOTE: All chargrill models incorporate a push button piezo ignition system for each individual pilot burner.
  • Page 17: Griddle Plate Fitting

    Operation Griddle Plate Fitting. The following options of griddle plate (Fig 4) can be fitted to the chargrill:-  (A) Griddle Plate 300mm or 450mm wide - (cast).  (B) Griddle Plate 300mm or 450mm - (fabricated). NOTE: If fitting a Griddle Plate to your Fig 4 chargrill, remove the required cast...
  • Page 18: Cleaning And Maintenance

    Cleaning and Maintenance General Caution Always turn ‘Off’ the gas supply before cleaning. This appliance is not water proof. Do not use water jet spray to clean the interior or exterior of this appliance. Clean the chargrill regularly. A clean chargrill looks better, will last longer and will perform better. Carbonised grease on the cooking surface or on the chargrill will hinder the transfer of heat from the cooking surface to the food.
  • Page 19: Weekly Cleaning

    Cleaning and Maintenance Weekly Cleaning NOTE:  If chargrill usage is very high, we recommend weekly cleaning is carried out more frequently.  Ensure protective gloves are worn during cleaning.  DO NOT use harsh abrasive detergents, strong solvents or caustic detergents as they will damage chargrill and burners.
  • Page 20: Periodic Maintenance

    Cleaning and Maintenance Main Burners a. Clean main burners with hot water, a recommended detergent solution and a scrubbing brush. Ensure any excess water is removed from inside the burners. Dry all burners thoroughly with a dry cloth. Fig 9 b.
  • Page 21: Fault Finding

    Fault Finding This section provides an easy reference guide to the more common problems that may occur during operation of your equipment. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
  • Page 22: Gas Conversion And Specifications

    Gas Conversion and Specifications Conversion Procedure Caution Ensure Appliance is isolated from gas supply before commencing servicing. NOTE:  Gas conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning the appliance. ...
  • Page 23 Gas Conversion and Specifications Gas Regulator NOTE, Pin - NAT Gas / LPG / Butane Only. NOTE: Gas regulator supplied convertible between Natural NOTE, Pin Gas and LP Gas, but it’s outlet rotated for LPG pressure is fixed ex-factory and is NOT to be adjusted.
  • Page 24: Gas Specifications

    Gas Conversion and Specifications Gas Specifications - Australia Natural Gas LP Gas (Propane) CH8600G CH8600G CH8300G CH8450G CH8900G CH8300G CH8450G CH8900G CH8120G CH8120G Main Burner Injectors 2.70mm 3.50mm 2.70mm 1.65mm 1.90mm 1.65mm Pilot Burner Injectors 0.35 0.45 0.25 0.30 turns out...
  • Page 25 Gas Conversion and Specifications - United Kingdom Appliance Classification Category: (20, 30 / 37). 2H3P Flue Type: Natural Gas (G20) Propane (G31) CH8600G CH8600G CH8300G CH8450G CH8900G CH8300G CH8450G CH8900G CH8120G CH8120G Main Burner Injectors 2.70mm 3.50mm 2.70mm 1.65mm 1.90mm 1.65mm...
  • Page 26 Gas Conversion and Specifications - All Other Markets Natural Gas Town Gas (**) CH8600G CH8600G CH8300G CH8450G CH8900G CH8300G CH8450G CH8900G CH8120G CH8120G Main Burner Injectors 2.70mm 3.50mm 2.70mm Ø 4.50mm T.B.A. Ø 4.50mm Pilot Burner Injectors 0.35 0.45 0.60m 0.75mm...
  • Page 27: Replacement Parts List

    If the part required is not listed below, request the part by description and quote the model and serial number which is on the rating plate. CHARGRILL - PARTS LIST Part No. Description CH8300G CH8450G CH8600G CH8900G CH8120G 227286 BURNER  ...
  • Page 28 Replacement Parts Gas Regulators Gas Regulators Gas Type Model Part No. Description CH8300G 228533 ½” BSP F/F Convertible. CH8450G Nat. Gas CH8600G LPG (Propane) 228531 ¾” BSP F/F Convertible. Butane CH8900G CH8120G Town Gas 230185 ¾” BSP F/F Adjustable. Gas Conversion Kits...

Table of Contents