Omron NX Series Hardware User Manual page 181

Machine automation controller
Hide thumbs Also See for NX Series:
Table of Contents

Advertisement

Additional Information
Procedure to Remove Tight Ferules
Use the following procedure to remove tight ferrules.
1. Press a flat-blade screwdriver at an angle into the release hole.
The appropriate angle of the screwdriver is 10 to 15° to the horizontal.
The tip of the flat-blade screwdriver contacts the ferrule if you press the driver too deep, and
this makes the ferrule difficult to be pulled out. Press the flat-blade screwdriver lightly and
stop there when you feel some resistance.
2. Leave the flat-blade screwdriver pressed into the release hole and tilt the flat-blade screw-
driver approximately 5° to the direction of the ferrule.
The position of spring in the release hole changes by the tilted flat-blade screwdriver, and
this creates a gap between the ferrule and the spring.
3. Leave the flat-blade screwdriver tilted and pull out the ferrule.
4. Remove the flat-blade screwdriver from the release hole.
Removing a Terminal Block
NX-series NX502 CPU Unit Hardware User's Manual (W629)
Flat-blade screwdriver
(1)
10 to 15°
(2)
(3)
(4)