Bus Unit Power Supply - Omron NX Series Hardware User Manual

Machine automation controller
Hide thumbs Also See for NX Series:
Table of Contents

Advertisement

Internal
power
supply
circuit
Unit power supply terminals
Unit power supply
(24 VDC)
Example of NPN type
*1. Wire colors have been changed according to revisions in the JIS standards for photoelectric
and proximity sensors. The colors in parentheses are the wire colors prior to the revisions.
4-1-3
X Bus Unit Power Supply
The X Bus Unit power is supplied directly from the Unit power supplied to the CPU Unit. Therefore,
external power supply is not required.
A total of 50 W of DC power can be supplied.
NX-series NX502 CPU Unit Hardware User's Manual (W629)
NX-series
Additional
I/O Power
NX502 CPU Unit
Supply
Unit
Internal circuits
NX Unit power supply
NX bus connector
I/O power supply
I/O power supply terminals
I/O power supply
(24 VDC, etc.)
I/O Power Supply
I/O Power Supply
Connection Unit
Connection Unit
(IOV terminals: 16)
(IOG terminals: 16)
NX-PC0020
NX-PC0010
A1
B1
A1
IOG
IOG
IOV
IOV
IOV
IOV
IOG
IOG
IOV
IOV
IOG
IOG
IOG
IOG
IOV
IOV
IOV
IOV
IOG
IOG
IOG
IOG
IOV
IOV
IOV
IOV
IOG
IOG
IOV
IOV
IOG
IOG
A8
B8
A8
4 Designing the Power Supply System
NX Unit
I/O
I/O
Power
Power
Supply
Supply
Connec-
Connec-
tion Unit
tion Unit
I/O power supply is not
separated at the I/O
Power Supply Connection
Units.
DC Input Unit
Two-wire sensor*1
(NPN type)
(limit switches, etc.)
NX-ID5342
B1
A1
B1
Brown (White)
0
1
Blue (Black)
2
3
4
5
7
6
8
9
Three-wire sensor
10
11
with NPN output*1
(photoelectric
13
12
sensor, proximity
14
15
sensor, etc.)
B8
A8
B8
Black (White)
Brown (Red)
Blue (Black)
End
Cover
NX Unit
Not enough I/O
power supply
terminals
4
4-9