Before mounting and using the pump for the first time,
check and retorque all external fasteners. Follow
Torque Instructions, page
tag on your pump. After the first day of operation,
retorque the fasteners.
Flush the
the Pump
Pump Before
Before First
Flush
Flush
the
Pump
Before
The pump was tested in water. If water could
contaminate the fluid you are pumping, flush the
pump thoroughly with a compatible solvent. See
Flushing and Storage, page
Transfer Mode
Mode Vs.
Vs. Low
Transfer
Transfer

Mode

Vs.
Mode
Mode
Mode
When the air pressure is at least 0.7 bar (10 psi)
higher than the desired outlet pressure, the pump
is in Transfer Mode and no pulsation damping
is occurring. To reduce outlet pulsation, start by
equal
setting the air pressure
fluid pressure. Continue to adjust the air pressure
relative to the outlet fluid pressure. Lower relative air
pressures produce more pulsation damping. Higher
relative air pressures produce better pump efficiency.
Start and
and Adjust
Adjust the
the Pump
Start
Start
and
Adjust
the
1. Be sure the pump is properly grounded. See
Ground The System, page
859.0761
All manuals and user guides at all-guides.com
22, or see the torque
First Use
Use
First
Use
21.
Low Pulsation
Pulsation
Low
Pulsation
to the desired outlet
Pump
Pump
13.
2. Check fittings to be sure they are tight. Use a
compatible liquid thread sealant on male threads.
Tighten fluid inlet and fluid outlet fittings securely.
3. Place the suction tube (if used) in fluid to be
pumped.
NOTE: If fluid inlet pressure to the pump is more
NOTE:
NOTE:
than 25% of outlet working pressure, the ball
check valves will not close fast enough, resulting
in inefficient pump operation.
NOTICE
NOTICE
NOTICE
Excessive fluid inlet pressure can reduce
diaphragm life.
4. Place the end of the fluid hose into an appropriate
container.
5. Close the fluid drain valve.
6. Turn the air regulator knob to match the desired
fluid stall pressure. Open all bleed-type master
air valves.
7. If the fluid hose has a dispensing device, hold it
open. Be sure all fluid shutoff valves are open.
8. Set the desired frequency on the VFD.
9. Press the start (run) button on the VFD.
10. If you are flushing, run the pump long enough to
thoroughly clean the pump and hoses.
Operation