The atomizer chamber consists of a patented design which disperses treatment evenly
to each seed. A motor drives the atomizer head at approximately 1725 RPM's. As
treatment is being pumped into the atomizer chamber, it drops into the atomizer head.
The centrifugal force of the spinning head forces the treatment to be sprayed out
through a screen covering in all 360 degrees. Meanwhile, seed flows down out of the
seed wheel and down on top of the distribution cone which disperses the seed down
around the atomizer head. The atomizer can be easily accessed for cleaning and
maintenance by pulling down on the quick release handle and sliding the atomizer
away from the treater body (see page 56).