Conair GB/ WSB User Manual page 73

Gravimetric blenders
Table of Contents

Advertisement

RETRIES:
(DATA line 3 and 1, FIRST and FINAL dispense)
When FIRST time dispense, (DATA line 3), does not equal FINAL dispense,
(DATA line 1), one or more retries have occurred.
of a problem that will also cause percentage errors.
Retries may indicate possible problems;
material, or the flow rate is so erratic that the first dispense was
short for no good reason.
shortage error is necessary to force a retry.
FLOW RATE NUMBERS: (DATA line 2)
Check the RATE numbers, (DATA line 2), to determine each dispense
device.
In the example above:
In the REGRIND column, 18224 and 976 translate to 1822.4 grams in 4
seconds (244 interrupts = 1 sec), or 455.6 grams per second, typical
for a regrind flowing through 3" round or 2"x3" dispense valves.
In the NATURAL column, 19993 and 488 indicate 1999.3 grams in 2
seconds, or 999.6 grams per second flow rate.
material, not polyethylene.
In the COLOR column, 12973 and 31232 indicate 1297.3 grams per 31232
interrupts, or 128 seconds, for a flow rate of 9.99 grams per second.
This is a 1 inch auger feeder, from which we would typically expect
about 8 grams per second.
delivering about 16 grams per second.
In the ADDITIVE column, 10240 and 31232 indicate a flow rate of 8 grams
per second EXACTLY.
are, in fact, the "default" settings from when the blender was first
installed, we know that "Additive" has never been run on this blender,
or at least not since the last "CLEAR ALL" was performed.
DATA line 3 dispense weight of 0.0 for additive, and the TOP-OF-PAGE
heading showing Additive set to 00.0 percent also confirm that Additive
is not being run.
The following information will help you determine what devices are in
place on a blender.
Device:
1/2 inch augers, micro pulse valves
1 inch augers, 60 RPM motors
1 inch augers, 120 RPM motors
100 series valves dispense
3" round and 2x3 inch valves
900 and 1800 series large 3x6 valves
3" round and 2x3 valves with flow restrictors
Regrinds are always lower then naturals.
wide variations in flow rates.
Parameters _RT and _RP determine what
Perhaps Lexan or a glass filled material.
More recent auger feeders use faster motors
Since it is exact, and since these two numbers
Approximate grams per second:
Page 74
Retries are evidence
perhaps the hopper ran out of
This is a heavy natural
1/2 to
6 to
12 to
250 to
500 to
3000 to 5000
50 to
Bulk density will also cause
2
10
20
450
900
100

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

GbWsb

Table of Contents