Conair GB/ WSB User Manual page 38

Gravimetric blenders
Table of Contents

Advertisement

*57
For LIQUID COLOR applications only.
operates in conjunction with an additional two air solenoids
mounted on the blender frame.
Press (*,5,7) to allow automatic switch over to a full drum
when the current drum of color runs out.
off, display will say (COL= 4 ).
4+7).
to output 4 only, the standard COLOR output.
says (COL= 4+7), this means that output 4 is the starting
output, and when no weight is detected after a dispense, the
output switches to output 7.
parameter (LIQ 00007).
by changing the parameter.
If output 7 is also empty, the output switches back to 4.
See parameter (LIQ 00007) for more information.
*66
Press (*,6,6) to enter an identification number for this
particular weigh scale blender. This I.D. number will appear
on all printed reports. If you have more than one unit, this
helps to identify reports. If you are using a computer to
automatically gather data, then each controller must have a
unique address. Valid numbers are 000 to 255.
be consecutive.
not use the number 000 for identification.
*69
Press (*,6,9) to set flag to treat the "REGRIND" dispense as
a SECOND NATURAL material.
With the flag OFF, Natural is calculated to fill the space
remaining in the weigh bin after a Regrind dispense has
occurred.
is dispensed, additional Natural is dispensed.
Additive dispenses are calculated as a percentage of this
Natural dispense ONLY.
With the flag ON, Natural is calculated to maintain the
proper RATIO between the two components (Natural and
Regrind).
add to BOTH components at the requested ratios.
"Regrind", in the normal sense, is not added.
component is treated as another "Natural" material.
ratio of the two naturals is not 50/50, place the HIGHER
volume component in the "regrind" side.
thumbwheel for the percentage that the "regrind" side is of
the combined mix.
used at a 20/80 mix ratio; B is the greater at 80 percent.
Put component B in the regrind side and set the regrind
switch for 80 percent.
NOTE:
set to a number that forces retries and stops the system
when this component runs out. See PARAMETERS, RAL-00004.
Use the * key to toggle flag ON or OFF.
Press EXIT when desired flag status is displayed.
When display says (COL= 4 ), the color setting aplies
When units are connected to a computer, do
In other words, when a reduced amount of Regrind
Color and Additive dispenses are calculated to
For example; Naturals A and B are to be
The Regrind alarm parameter (RAL) is automatically
Page 39
This function usually
Press * to toggle to (COL=
The "7" is determined by the
You can change the secondary output
When function is
When display
They need not
Color and
Instead, this
If the
Set the "regrind"