Conair GB/ WSB User Manual page 39

Gravimetric blenders
Table of Contents

Advertisement

NOTE: Do not use these features in combination with *82.
*71 and *72
Press (*,7,1) to change the Color setting to be interpreted
as percent of the entire MIX instead of percent of the
Natural.
the same way.
The display will say (CPM -OFF) or (APM -OFF).
toggle flag to (CPM -ON) or (APM -ON).
Color Percent of Mix, APM for Additive Percent of Mix).
These options has been added for a customer with a unique
requirement.
Leave these flags OFF unless you have specific instructions
to do otherwise.
CAUTION:
combined must NOT exceed 100 percent.
standpoint, they should not exceed 20 percent combined.
*74
Press (*,7,4) to set a flag that will cause the system to
stop and the Alarm to activate when MAX weight is exceeded.
This might occur if a valve sticks open or slightly open.
Normally the system recovers automatically from such events
with only the one batch blended incorrectly.
only if you want the system to stop and alarm.
Press * key to toggle between (MAX
Press EXIT when done.
*75
Press (*,7,5) to set a flag to ALARM if the weigh bin weight
drops more them 20 grams during a cycle.
detect and report a weigh bin problem, such as material
leaking from the bottom of the bin.
*77
Press (*,7,7) to print a copy of all internal parameters.
printer must be connected and ready.
print since parameters reside in four different locations in
memory: RAM; ROM, both WSB2 and WSB9 default listings; and
EEPROM.
*78
Press (*,7,8, followed by a 5 digit number) to change the
PASSWORD number for entering the PROGRAM mode.
is supplied with the number "22222" as the password number.
If you wish to restrict use of this mode to only yourself,
you may make up your own number and enter it here.
If you forget your password number, call us for help.
*82
Press (*,8,2) to produce a precision ratioing of either the
Color or Additive.
between (P/R OFF), (P/R
If precision rationing is selected, the Color (or Additive)
dispense occurs BEFORE the Natural, instead of after.
This flag for SPECIAL APPLICATIONS ONLY.
Press (*,7,2) to change the Additive setting in
With flags set, Color and Additive settings
Identifying headings print above each columns.
Press CE (previously *) to toggle
Page 40
(CPM stands for
From a practical
OK ) and (MAX ALARM).
Four columns will
COL) or (P/R
ADD).
Press "*" to
Set the flag
This serves to
The system
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

GbWsb

Table of Contents