Conair GB/ WSB User Manual page 59

Gravimetric blenders
Table of Contents

Advertisement

This rate is used to calculate an exact time period to dump the
required quantity of material.
Both of these numbers are adjusted by the computer logic after
each cycle as a means of continuously calibrating the dispense times.
This rate correction takes place continuously and the battery-
backed RAM maintains the correct rate even when power is turned off.
If, for some reason, you were to set these numbers manually, (for
example, if the load cells are damaged and you want to adjust the
VOLUMETRIC flow rate),
follows:
For a 1" auger feeder with a 60 RPM motor; this unit
dispenses 8 grams per revolution which is 8 grams per second.
the _WT gram number indicates tenths of grams (model 2xx) and the _TI
number indicates interrupts (at 244 per second) then the proper numbers
would be:
The computer automatically bumps both numbers up in value by
doubling them both until at least one number exceeds 16,000.
(rate) is still the same but error correction routines work better with
higher numbers.
======================================================================
_MI
(set AUTOMATICALLY each time power is turned on.)
_MI numbers are set to one half the amount of material, in grams,
that can feed in one second based on normal valid dispense rates.
valid rate is considered the normal dispense rate that occurs under
normal conditions with equipment functioning properly.
lower than half this actually occurs, it is assumed that an equipment
malfunction or loss of material has occurred.
circumstances, normal rate correction routines are bypassed.
EXAMPLE:
normal metering rate is about 8 grams per revolution or 8 grams
per second.
(model 2xx), half of this is expressed as (_MI 00040).
It is safe to use a _MI number that is too low but NOT safe to use
a number too high.
this number is too high.
This number is reset to 00001 every time power is turned on.
After the system detects 10 good dispenses, (no retries, no bailouts),
then the MI parameter is AUTOMATICALLY set to 50 percent of current
flow rate.
The RATE CALIBRATION routine will also set this parameter.
Periodically, during production, if dispenses have occurred in a very
uniform manner for an extended period of time, the MI parameter is
reset based on these dispenses.
======================================================================
_NC
(changes itself AUTOMATICALLY over time)
_NC is the allowable GRAM error within which NO flow rate
corrections are made by the software.
equal to, or less than, this number will be accepted and no error
an example of a proper setting would be as
_WT 00080
For a 1" auger feeder with a 60 RPM motor drive, the
Since the _MI number is expressed as tenths of grams,
Error correction routines will not work when
Page 60
and
_TI 00244.
Under these
Gram weight errors that are
Since
The ratio
A
When a rate