JOG 03030
Mix blade JOG count and interval
This parameter sets how many jogs will occur and how often.
FCV 00006
TIME the Flow Control valve delays before opening (sec.).
This parameter holds each batch in the mix chamber for a time to
assure mixing.
flow control valve under the mix chamber.
DTI 00006
Weigh bin dump TIME at end of cycle. (seconds)
This parameter sets the maximum open, or dump time for the weigh
bin.
No change is required.
KDF 00010
Maximum variation in GRAMS between two consecutive weight
WDF 00010
readings for reading to be accepted. (x or x.x)
KDF controls sensitivity of weight readings during calibration of
load cells.
WDF controls the sensitivity of weight readings during normal
operation.
readings you may have to increase this number.
BER 00200
Excess GRAM weight before dispense is aborted.
This parameter controls sensitivity of the emergency "bailout"
routine that prevents overfilling of the weigh bin.
No change is required.
CXT 00000
Move decimal left on color and additive settings.
AXT 00000
These parameters allow entry of less then (00.1) percent for
COLOR or ADDITIVE.
When set to "00010" settings are read as X.XX percent.
When set to "00100" settings are read as .XXX percent.
ROC 00000
These three parameters help control regrind usage.
ROV 00000
RHL 00000
ROC indicates the PERCENT of REGRIND that will be treated as
natural when COLOR and ADDITIVE dispenses are calculated.
This adds some color or additive to your regrind.
ROV is for closed loop fully automatic reprocessing of regrind
scrap. This parameter will detect when more regrind is being
produced than consumed, and override the current setting to
use a higher amount.
in your grinder.
RHL has effect only if level sensors are added to your unit to
detect material level in the regrind hopper.
sensors can alter regrind percent usage.
FUL 20000
Full batch weight, determined by weigh bin size.
MAX 30000
Maximum GRAM weight the software will target.
FUL is the target weight that is blended each cycle. Change only
This is only for units equipped with the optional
No change is required.
If excessive vibration interferes with weight
This helps prevent material backing up