Conair GB/ WSB User Manual page 57

Gravimetric blenders
Table of Contents

Advertisement

_SE
(This might be useful)
_SE is the upper SETTING limits for the thumbwheel switches.
allows a reasonable cap to be set for each component so that an
operator cannot accidentally set the controls to an excessively high
setting.
For color and additive, these limits will ensure that
expensive material is not wasted.
than the limit are held to the limit.
EXAMPLE:
may enter this upper limit in the parameter table.
are stored as 1/10s of percent (##.#), the parameter would be:
Color thumbwheel settings above 060 will be held to 6 percent.
NOTE: If you wish to positively fix the settings so that the thumbwheel
switches have no control and no one can change them without
authorization, you may do this by using the KEYPAD to enter any or
all settings.
+---------------------------------------------------+
¦ Press:
¦ Press:
¦ Press:
¦ Press:
¦
¦ Enter:
¦
¦ Press:
+---------------------------------------------------+
An LED will light indicating this override condition.
only when the thumbwheel does not match the internal setting.
To later return to thumbwheel control, use the same procedure as
above except instead of entering a setting, press the "CE" key
when you see the setting displayed.
The operator may still prevent running this component by entering
a setting of all ZEROS (00.0).
entered by the keypad.
enter a 1 as the first digit in the SE parameter.
======================================================================
RLO
(probably no need to ever change this)
RLO is the lower limit for SETTING the regrind thumbwheel
switches.
Settings lower than this number will be held to the low
limit.
Air operated dump valves are not intended to dispense very
small quantities.
allowing a minimum dispense of 5% or about 100 grams.
======================================================================
DLY
(consider changing if mixing is a problem)
DLY is the TIME the mix chamber level sensor must be uncovered
before a cycle begins.
If the highest color usage in your plant is 6%, you
CSE 00060
To do so:
*
Display will say:
22222
Display will say:
SET
Display will say:
COL (or ADD or REG)
Display will say:
New setting
EXIT
Display will say:
If you do not want this override option,
We have set RLO at the factory to 5 percent (00050)
The sensor must be uncovered without
Page 58
Thumbwheel settings that are greater
(PASSWORD) ¦
(P
(SETTING ) ¦
(C = xx.x) ¦
(P
This will override any setting
This
Since settings
x) ¦
¦
¦
¦
xxxxx) ¦
This occurs
(_SE 1xxxx)