Agilent Technologies E7474A Getting Started Manual page 63

Drive test wireless solutions
Hide thumbs Also See for E7474A:
Table of Contents

Advertisement

NOTE
Setting Up Your System
Receiver and Phone-Based System Setup
9. Connect the phone cable to a second COM port (different than used in
step 1). On most laptop PCs this will require the use of a Socket Serial I/O
RS-232 card that is installed into the PCMCIA slot on your PC.
10. Turn on the Trimble Placer GPS 455, the Agilent E645x receiver, the PC,
and phone.
11. Calibrate the DR unit using Trimble supplied software Plcrinit.exe or
GPSSK. If you do not have this software, it is available on the Trimble
web page. For more details and the URL, refer to
12. Start the Agilent Technologies application software. Verify that both the
software and the Trimble Placer GPS 455 are configured for the same
communication protocol.
13. Configure the Trimble Placer GPS 455 unit for the correct settings. See
"Selecting GPS Hardware" on page 3-4 for more information.
14. Configure the phone:
a. Select Configuration mode.
b. Select the Hardware tab.
c. Double-click the phone icon or select the phone icon and click
d. In the Hardware Type box, select the phone used.
e. Click the Port Selections and Port Settings tabs to modify and confirm
the correct COM port setting for the phone. The port selection should
be serial and select the Com port you are using.
f.
Use the default port settings or use the values according to the
PCMCIA Socket I/O card you are using.
g. Click
when you are satisfied with the settings.
OK
h. Select Collection mode to start the measurements.
Never set your GPS receiver protocol as TAIP and TSIP together. The
Agilent Wireless Solutions Software is designed to work with one protocol at
a time. Having both protocols active may confuse the system.
70
page
20.
Modify
Agilent Wireless Solutions
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

E7473aE7475aE7476aE7477aE7490a

Table of Contents