Agilent Technologies E7474A Getting Started Manual page 141

Drive test wireless solutions
Hide thumbs Also See for E7474A:
Table of Contents

Advertisement

Verifying the System
Method 4: GPS Measurement Verification Procedure
In order to configure any GPS unit, you have to know the settings of that unit.
The default settings of the Trimble GPS units supported by Agilent have been
included in the Agilent Wireless Solutions Software. New settings can be
selected using Port Settings Tab of the Hardware Editor in Configuration
Mode. See
Table 4-5 on page 153
Table 4-5 GPS Settings
Protocol
Bits per Second
Data Bits
Parity
Stop Bits
Flow Control
a. The SVeeSix Plus GPS Unit is built by TRIMBLE to work only as TSIP, NMEA, or TAIP
according to the last 2 digits of the part number:XXXXX-61 is TSIP only; XXXXX-62 is NMEA
only; XXXXX-63 is TAIP only. Verify first what protocol is used, to find out the default settings
of that unit.
b. The GPS 455 unit can work as TAIP or TSIP. By default it is configured as TAIP. If you want the
unit to work as TSIP, you must set the GPS 455 to TSIP.
Agilent Wireless Solutions
for the default settings.
Trimble Placer
Trimble Placer
GPS/DR
GPS 400/
SVeeSix Plus
TAIP
TAIP
4800
4800
8
8
None
None
1
1
None
None
Trimble Placer
Internal GPS
GPS 455
(Trimble Placer
a
Model SK-8) or
SVeeSix Plus
b
TAIP
TSIP
9600
9600
8
8
None
Odd
1
1
None
None
153