Troubleshooting

Known constraints
Archive Writer error
messages
A-61038
July 1999
After powering the host PC off and on, the Archive Writer is
inoperational.
Remove the RS-232 connection to the Archive Writer (either at
the Archive Writer or the host), then reboot the Writer.
The dates of the files of the Archive Writer are incorrect.
The files were created with the correct date and time, but NT
interprets the time at Greenwich mean time and corrects for the
local time zone and daylight savings time vs standard time. The
situation should only appear when viewing the directory listing of
the Archive Writer's disk via NT Explorer or the dir command in a
DOS command window.
Following are messages and descriptions of error codes you may
encounter when using the Kodak Digital Science Document
Archive Writer. Other error codes may occur. If they persist, call
your Integrator or call for service.
103
Cassette door closed
The cassette access door was closed.
200
Check film supplies
The film remaining in the upper cassette is equal to or less
than 3 feet (91 cm).
Place a new roll of film in the cassette.
201
Check film supplies
The film remaining in the upper cassette is equal to or less
than 10 feet (3.05 m).
Place a new roll of film in the cassette.
202
Check film supplies
Check film supplies. The film remaining in the upper
cassette is equal to or less than 15 feet (4.55 m).
Place a new roll of film in the cassette.