5. Load Characteristics
Rated Load
(AC)
20A / 250V

6. Installation Method

This product does not have a waterproof function. After the network configuration is completed, please
place it indoors
Notice:
1. When the detected current exceeds the measurement range (20A), the device will automatically
disconnect the load within 2 seconds after the detection, and check whether the Bit1 (Current OverLoad)
of the attribute ACAlarmsMask is 1. If it is 1, the device will sent an alarm, 0 for no alarm.
AlarmCluster = 0x0B04, AlarmCode = 0xF0; network light (using red light) flashes 10 times (10,250,250)
2. If the storage chip of Z810B is AT2401, it will save it every 30 seconds, if it is AT2402, it will save it
every 10s, and other high-capacity storage such as AT2404/08 will save it every 1 second, so the data
within 30/10/1 second will be lost due to power failure.
Max. Inductive
Max. Load
with LEDs
100W / 1 LED
Max. Load with
Load
Electric Motors
(cosφ=0.4)
5A / 250V
2HP / 250V
Overload
Protection with
Auto Power
Cutoff
Yes