netvox Z810B User Manual page 14

Wireless load control 2t with power/energy/current/voltage meter and lcd
Table of Contents

Advertisement

Identifier
0xE001
0xE002
0xE003
(8) Attribute of Electrical Measurement
Identifier
0x0000
MesurementType
0x0505
RMSVoltage
0x0508
RMSCurrent
0x050B
ActivePower
0x050E
ReactivePower
0x050F
ApparentPower
0x0510
PowerFactor
0x0600
ACVoltageMultiplier
0x0601
ACVoltageDivisor
Name
Unsigned
Voltage
16-bit
integer
Unsigned
Power
16-bit
integer
Unsigned
Energy
32-Bit
integer
Name
32-bit
bitmap
Unsigned
16-bit
integer
Unsigned
16-bit
integer
Signed
16-bit
integer
Signed
16-bit
integer
Unsigned
16-bit integer
Signed
integer
Unsigned
16-bit
Unsigned
16-bit
integer
Type
Range
0x0000 -
0xFFFF
0x0000 -
0xFFFF
0x00000000
-
0xFFFFFFF
F
Type
Range
0x00000000
-
0xFFFFFFF
F
0x0000 -
0xFFFF
0x0000 -
0xFFFF
-32768 -
32767
-32768 -
32767
0x0000 -
0xFFFF
-100 to
8-bit
+100
0x0001 -
0xFFFF
integer
0x0001 -
0xFFFF
Access
Default
Read
0x0000
Only
Read
0x0000
Only
Read
0x00000000
Only
Access
Default
Read
0x0000000
Only
F
Read
0xFFFF
Only
Read
0xFFFF
Only
Read
0xFFFF
Only
Read
0xFFFF
Only
Read
0xFFFF
Only
Read
0x00
Only
Read
0x0001
Only
Read
0x0001
Only
Mandatory
/ Optional
O
O
O
Mandatory
/ Optional
O
O
O
O
O
O
O
O
O

Advertisement

Table of Contents
loading

Table of Contents