4.7 Electric energy, power, voltage, current switching display

On the energy display interface, short press the Energy Key button to switch to voltage (in volts),
current (in amps), power (in watts), and electric energy (in kWh).
Note: The device can also automatically refresh the power interface, which is refreshed every 5 seconds.

4.8 Data reporting time

When the binding request is successful, the device sends data to the device in the binding request.
In the case of no configuration time, the default minimum time of Z810B's 0x0505\0x0508\0x050B
attribute is 180 seconds, the maximum time is 300 seconds, and the reportable change is 100.
0x0510 attribute default minimum time is 180 seconds, the maximum time is 300 seconds, and the
reportable change is 100.
Z810B's 0x0000, 0xE000, 0xE001, 0xE002, 0xE003 attributes default minimum time and maximum
time are 0xFFFF, and reportable change is 100, which means no report by default.
Min Interval / Max Interval setting:
Min Interval
0x0001-0xFFFE
0x0000
0x0001-0xFFFE
0x0000
0x0001-0xFFFE
*When the reportable change value is 0, the report will be sent according to the Min interval.
*The Reportable change of each attribute can be configured according to the specific load power consumption situation.
Max Interval
ReportChange
0x0001-0xFFFE
0x0001-0xFFFE
0x0000
0x0000
0xFFFF
When data<
ReportChange
Max Interval
report
Max Interval
report
>0
Do Not Report
Do Not Report
Turn off the report
of this attribute
When data≥
ReportChange
Min Interval
report
Immediately
Min Interval
report
Immediately
Turn off the report
of this attribute