4.12 Product attributes and custom instruction description

1. The Cluster used by Z810B refers to the Cluster ID (0x0702) and Electrical Measurement Cluster ID
(0x0B04) used by Simple Metering in SE, and in the Cluster ID (0x0702), NETVOX has customized
the attributes of current, voltage, power, and electric energy.
Cluster ID (0x0B04):
(1) The Attribute ID used for the current attribute is: 0x0508, and the voltage attribute is 0x0505.
(2) The power attribute uses Attribute ID: 0x050B, and the power factor attribute is 0x0510.
Cluster ID (0x0702):
(1) The custom current attribute uses Attribute ID: 0xE000, and the custom voltage attribute is
0xE001.
(2) The custom power attribute uses Attribute ID: 0xE002, and the custom electric energy attribute is
0xE003.
(3) The attribute CurrentSummationDeliver whose AttributeID is 0x0000 corresponds to the electric
energy attribute 0xE003.
(4) Electric energy ATTRID = 0xE003 (or 0x0000), the unit is wh. power ATTRID = 0xE002, the
unit is w. Current ATTRID = 0xE000, the unit is mA; Voltage ATTRID = 0xE001, the unit is V
2. Custom directive
The command to erase the current power information is: 0xE0. The command format is:
Bits: 8
Frame
control
0x05
16
Manufacturer
code
0x109F
(clustered: 0x0702, Action: 0x00)
8
Transaction
Sequence
number
8
Frame payload
Command
identifer
0xE0
8
Action
0x00