Page 1
Z810B Wireless Load Control 2T with power/energy/current/voltage meter and LCD Wireless Load Control 2T with power/energy/current/voltage meter and LCD Z810B User Manual...
4.8 Data Reporting Time ..........................7 4.9 Factory Reset ............................8 4.10 Erase Power Information ......................... 8 4.11 Clusters Of Home Automation For Z810b ..................... 9 4.12 Product Attributes And Custom Instruction Description ..............16 6. Installation method ............................17...
Z810B device acts as a simple metering device that provides the user with current consumption (load current, load voltage, power, and energy) Z810B can report its readings to a display device or a PC. This device can be switched through paired switch wirelessly or through the manual switch button.
3. Appearance AC_N IN AC_L IN Match Key Bind Key AC_N OUT AC_L OUT 4. Operating Instructions 4.1 Power On Connect the Z810B device to an AC 100-240V power supply, power on the device, and the LCD backlight will light up.
Z810B in the network. (b) If Z810B is used as a router in the network, it will actively search for the network after power-on and will keep flashing before it joins the network, and the value area will display power information.
4.6 Allow joining the network function As a router in the network, Z810B has the function of allowing other devices to join the network as its sub-devices. Simultaneously press the binding key and the function key for 1 second, the icon...
When the binding request is successful, the device sends data to the device in the binding request. In the case of no configuration time, the default minimum time of Z810B's 0x0505\0x0508\0x050B attribute is 180 seconds, the maximum time is 300 seconds, and the reportable change is 100.
4.9 Factory reset After Z810B joins the network, it will save its assigned network address. If you want to join a new network, you need to restore the original factory settings first. After pressing and holding the binding key for 15 seconds, the...
4.11 Clusters of Home Automation for Z810B 1. End Point(s): 0x01 2. Device ID: Mains Power Outlet (0x0009) 3. Cluster ID supported by EndPoint Cluster ID for Z810B Client Side Server Side EP 0x01 (Device ID: Mains Power Outlet (0009))
Page 10
0x35 Only integer 8-bit Read 0x0003 HWVersion Unsigned 0x00–0xff 0x0B Only integer Character 0 – 32 Read 0x0004 ManufacturerName netvox string Bytes Only Character 0 – 32 Read 0x0005 ModelIdentifier Z810BE3R string Bytes Only Character 0 – 16 Read 0x0006...
Page 11
Mandatory Identifier Name Type Range Access Default / Optional Unsigned Read 0x0001 CurrentScene 8-bit 0x00 – 0xff 0x00 Only integer Unsigned 0x0000 – Read 0x0002 CurrentGroup 16-bit 0x00 0xfff7 Only integer Read 0x0003 SceneValid Boolean 0x00 – 0x01 0x00 Only Read 0x0004 NameSupport...
Page 12
Mandatory Identifier Name Type Range Access Default / Optional Any valid IEEE_ADDR Read 0x00000000 0x0010 Trust center address IEEE /Write 00000000 Address Trust center master SECURITY_ Any 128-bit Read 0x0011 0000000000 value /Write 5A 69 67 42 65 65 41 SECURITY_ Any 128-bit Read...
Page 14
Mandatory Identifier Name Type Range Access Default / Optional Unsigned 0x0000 - Read 0xE001 Voltage 16-bit 0x0000 0xFFFF Only integer Unsigned 0x0000 - Read 0xE002 Power 16-bit 0x0000 0xFFFF Only integer 0x00000000 Unsigned Read 0xE003 Energy 32-Bit 0x00000000 0xFFFFFFF Only integer (8) Attribute of Electrical Measurement Mandatory...
Page 15
Mandatory Identifier Name Type Range Access Default / Optional Unsigned 0x0001 - Read 0x0602 ACCurrentMultiplier 16-bit 0x0001 0xFFFF Only integer Unsigned 0x0001 - Read 0x0603 ACCurrentDivisor 16-bit 0x03E8 0xFFFF Only integer Unsigned 0x0001 - Read 0x0604 ACPowerMultiplier 16-bit 0x0001 0xFFFF Only integer Unsigned...
4.12 Product attributes and custom instruction description 1. The Cluster used by Z810B refers to the Cluster ID (0x0702) and Electrical Measurement Cluster ID (0x0B04) used by Simple Metering in SE, and in the Cluster ID (0x0702), NETVOX has customized the attributes of current, voltage, power, and electric energy.
AlarmCluster = 0x0B04, AlarmCode = 0xF0; network light (using red light) flashes 10 times (10,250,250) 2. If the storage chip of Z810B is AT2401, it will save it every 30 seconds, if it is AT2402, it will save it every 10s, and other high-capacity storage such as AT2404/08 will save it every 1 second, so the data...
7. Important Maintenance Instruction As the device is not water proof it is recommended to keep the device in a dry place. Liquid and heavy moisture contains minerals that may oxidize the electronic circuitry. In case of liquid spill, please leave the device to completely dry before storing or using.