5 Drying

5
Drying
WARNING!
Make sure that no cleaning residues remain and that the components, especially the valves, are completely dry after
drying process before assembly. Ingress of water can cause icing inside the device if not carefully dried.
Failure to follow this warning can result in serious personal injury or death.
Higher temperatures and longer duration than recommended may cause the plastic and rubber materials to
age more quickly, shortening the service life of the equipment.
5.1

Air Drying (Drying in the Ambient Atmosphere)

The devices can be dried by natural means:
• in normal climate free of pollutants
• protected from direct sunlight
• protected from UV light
• protected from heating of more than 45 °C ± 5 °C for more than 1 h
Make sure that the temperature does not exceed 50 °C. Make sure that no detergent residues remain and that the
devices, especially the valves, are completely dry after drying process.
5.2

Drying in Drying Cabinet / Drying Chamber

For accelerated drying, a drying cabinet can be used (e.g. by Podab TS4) at a drying temperature of 45 °C ± 5 °C for
no longer than 60 minutes.
5.3

Preparation of Equipment

5.3.1

Facepieces

After drying reassemble facepiece in reverse order (see chapter
and dry.
After reassembling perform all required tests according to the dedicated operating or maintenance manuals.
5.3.2

Breathing Apparatus

Drying of the Pressure Reducer
1. Remove the cap seal ring from the pressure reducer.
24
4.3
2. Blow out remaining humidity from the pressure reducer with an air gun.
Blow out pressure reducer via ventilation bore holes.
Use compressed air with breathing air quality according to EN 12021.
One of the bore holes has to show downwards. Blow out in-depth and
dry completely.