2 Manual Decontamination / (Pre-)Cleaning
M1 Control Module (CM)
NOTICE
Do not remove the device from pneumatics. Always pressurize > 60 bar the device during (hand) washing.
Otherwise, ingress of water may damage the system or any components.
The device components should be cleaned after each operation and, if badly contaminated, with a damp cloth
(lukewarm water) and a little detergent.
For mechanical washing, follow detailed washing instructions for self-contained breathing apparatus.
The battery must always be connected to the device and the battery U-clip must be in the device.
Use the safety key to mute alarms.
WARNING!
After each successful decontamination, cleaning and disinfection the product/component must be tested/checked
according to the manufacturer's requirements described in the relevant operating or maintenance manuals before
the product/component is put back into service.
Failure to follow this warning can result in serious personal injury or death.
2.5.2
alphaBELT
There are two alphaBELT generations which differ in the materials used, as described below. It is important
to choose the correct washing procedure according to the alphaBELT version used!
• alphaBELT 1 version (first generation, green fabric pads, delivered until 2021)
• alphaBELT 2 version (second generation, M1 coated black pads, delivered since 2021)
alphaBELT 1 version only:
MSA has tested TURBO USONA by ECOLAB and recommends this product.
NOTE: Do not soak the belts, otherwise the labels can peel off.
1. Use lukewarm water (≤ 30 °C) and mild, pH-neutral detergent.
Dosage: 1% TURBO USONA detergent based on the amount of water used.
2. Rinse equipment with clear water after manual cleaning (≤ 30 °C).
Subsequent to the cleaning or disinfection process:
3. Dry the device completely (see chapter
4. Follow the information for maintenance and lubrication of the buckles in the relevant operating manual
(10156928).
alphaBELT 2 version only:
The alphaBELT 2 version (M1 coated black pads) is using the same fabrics as the M1 SCBA .
1. Clean with the detergents and process according to chapters
Subsequent to the cleaning or disinfection process:
2. Dry the device completely (see chapter
8
5
).
2.1.1
5
).
and
2.1.2
.
GB