3 Final Cleaning / Machine Cleaning
WARNING!
After each successful decontamination, cleaning and disinfection the product/component must be tested/checked
according to the manufacturer's requirements described in the relevant operating or maintenance manuals before
the product/component is put back into service.
Failure to follow this warning can result in serious personal injury or death.
3.3

Lung Governed Demand Valves

If the lung governed demand valve is mounted on the M1 SCBA, it can be cleaned together with it (see
Otherwise, the lung governed demand valve can be cleaned and disinfected separately (see chapter
1. Before connecting the unit to the medium pressure, switch off the lung governed demand valve by pressing the
red control button to prevent unintentional air supply (refer to the operating manual of the lung governed
demand valve).
2. Supply the lung governed demand valves with compressed air (breathing air quality) during the complete
washing sequence. Pressure range 3 to 8 bar.
3. Close the AE / ESA lung governed demand valve with the washing adapter AE / ESA (10200072), the AS lung
governed demand valve with the washing adapter AS (10200071).
4. Switch on the lung governed demand valve to produce a continuous air flow of approx. 5 l/min.
Subsequent to the cleaning or disinfection process:
5. Dry the device completely (see chapter
For further disinfection procedures, proceed according to the specification (see chapter
WARNING!
After each successful decontamination, cleaning and disinfection the product/component must be tested/checked
according to the manufacturer's requirements described in the relevant operating or maintenance manuals before
the product/component is put back into service.
Failure to follow this warning can result in serious personal injury or death.
3.4

Accessories

3.4.1

Electronics

Only some electronic devices are fully washable. Follow the special instructions and suitable cleaning procedures in
the respective manuals, e. g. M1 Control Module and SLS 2.0 are fully washable according to the procedures in this
manual.
WARNING!
Do not use any organic cleaning material for the cleaning of the individual components, such as nitro thinners,
alcohol, white spirit, petrol etc.
Failure to follow this warning can result in serious personal injury or death.
SingleLine SCOUT (SLS)
SingleLine SCOUT devices produced before July 2021:
After each operation and in case of heavy soiling, clean the device components with a damp cloth (lukewarm water)
and some detergent. The device should not be removed from the pneumatics for cleaning.