3 Final Cleaning / Machine Cleaning
Table 2 MSA recommendation for washing time
Machine type
Lightly soiled
MEIKO Topclean M* 10 minutes
Solo Rescue**
For facepieces only!
20 minutes main wash 10 minutes pre-wash + 20 minutes main wash
Miele***
* Decontamination + disinfection with complete water replacement after each cycle
** Decontamination only with complete water replacement after each cycle
*** Types: PW 6163, PW 6243, PW 6323, PW 6247, PW 6327, PWM 909, PWM 912, PWM 916, PWM 920
WARNING!
After each successful decontamination, cleaning and disinfection the product/component must be tested/checked
according to the manufacturer's requirements described in the relevant operating or maintenance manuals before
the product/component is put back into service.
Failure to follow this warning can result in serious personal injury or death.
3.1
Facepieces
Follow the cleaning procedures in the respective facepiece manuals.
NOTICE
It is not permitted to machine wash an anti-fog coated lens otherwise the coating will be damaged.
Preparing the Facepiece for Cleaning or Disinfection
1. Remove inhalation and exhalation valve discs.
2. Unbutton the nosecup.
3. Remove components that need to be separately cleaned and disinfected according to the relevant instructions
for use.
Subsequent to the cleaning or disinfection process:
4. Dry facepiece and components (see chapter
5. Perform tests according to the manufacturer's requirements described in the relevant operating or
maintenance manuals.
WARNING!
After each successful decontamination, cleaning and disinfection the product/component must be tested/checked
according to the manufacturer's requirements described in the relevant operating or maintenance manuals before
the product/component is put back into service.
Failure to follow this warning can result in serious personal injury or death.
12
Heavily soiled
20 minutes
9 min
5
) and reassemble facepiece in reverse order.
GB
Need help?
Do you have a question about the M1 Modular SCBA System and is the answer not in the manual?