MSA M1 Modular SCBA System Cleaning And Disinfection Manual page 11

Hide thumbs Also See for M1 Modular SCBA System:
Table of Contents

Advertisement

Table 1 MSA washing parameters
Machine type
Water softener
Cleaning agent(s)
Cleaning/disinfection
agent(s)
Washing procedure/
temperature
* The dosage has to be adjusted to the water hardness.
** Types: PW 6163, PW 6243, PW 6323, PW 6247, PW 6327, PWM 909, PWM 912, PWM 916, PWM 920
GB
MEIKO Topclean M
(by MEIKO
Solo Rescue
Maschinenbau
RESCUE Intellitech
GmbH & Co. KG,
AB, Sweden)
Germany)
Do not use chemical water softener. If necessary use osmosis modules recommended by
the machine supplier.
®
• EW 80
clean (1%)*
®
• EW 80
mat (1%) with Etolit GT 500
as rinse agent (0.25 ml/l)*
• Diversey Jade Pur Eco L8 (4 ml/l) with
Suma Med Neutral as neutralising
rinse agent (0.5 ml/l)*
Decontamination +
Disinfection:
Decontamination:
• 20 minutes at
45 °C + 5 °C,
after the
washing
cycle/process
has been
finished MSA
recommends a
complete bath
change (water
replacement)
For facepieces only!
®
(by
Miele** (by Miele & Cie. KG, Professional,
Germany)
• Dr. Weigert neodisher
(Forte 5 ml/l – 10 ml/l, 0.5 – 1%)*
• Ecolab Eltra
Decontamination:
• Masks (main wash, 4x rinse) at 60 °C
• 9 minutes at 45
Decontamination + Disinfection:
°C + 5 °C, after
the washing
• Masks (main wash, 4x rinse) at 60 °C
cycle/process
• Masks with pre-wash (pre-wash, main
has been
wash, 4x rinse) at 60 °C
finished MSA
• For the washing program see
recommends a
"Important Information for Cleaning
complete bath
and Disinfecting of Facepieces with
change (water
Miele** Washing Extractor" in chapter
replacement)
4.3.1.
3 Final Cleaning / Machine Cleaning
®
MediClean
®
(7 g/l)*
11