Preparation Of Equipment; Facepieces - MSA M1 Modular SCBA System Cleaning And Disinfection Manual

Hide thumbs Also See for M1 Modular SCBA System:
Table of Contents

Advertisement

Table 3 MSA recommendation for machine disinfection:
For facepieces and LGDV only!
Machine type
MEIKO Topclean M (by MEIKO
Maschinenbau GmbH & Co. KG, Germany)
Do not use chemical water softener. If necessary use osmosis modules recommended by the
Water softener
machine supplier.
• EW 80
Cleaning
rinse agent (0.25 ml/l)*
/disinfection
• Diversey Jade Pur Eco L8 (4 ml/l) with
agent(s)
Suma Med Neutral as neutralising rinse
agent (0.5 ml/l)*
Decontamination + Disinfection:
• 20 minutes at 45 °C + 5 °C, after the
washing cycle/process has been finished
Washing
MSA recommends a complete bath
Procedure/
change (water replacement)
temperature
Disinfection:
• 20 minutes at 45 °C + 5 °C with Diversey
Jade Pur Eco L8
• 5 minutes at 60 °C with EW 80
* The dosage has to be adjusted to the water hardness.
** Types: PW 6163, PW 6243, PW 6323, PW 6247, PW 6327, PWM 909, PWM 912, PWM 916, PWM 920
WARNING!
After each successful decontamination, cleaning and disinfection the product/component must be tested/checked
according to the manufacturer's requirements described in the relevant operating or maintenance manuals before
the product/component is put back into service.
Failure to follow this warning can result in serious personal injury or death.
4.3

Preparation of Equipment

4.3.1

Facepieces

Preparing the Facepiece for Cleaning or Disinfection
1. Remove inhalation and exhalation valve discs.
2. Unbutton the nosecup.
3. Remove components that need to be separately cleaned and disinfected according to the relevant instructions
for use.
Subsequent to the cleaning or disinfection process:
4. Dry facepiece and components (see chapter
5. Perform tests according to the manufacturer's requirements described in the relevant operating or
maintenance manuals.
GB
®
mat (1%) with Etolit GT 500 as
®
mat
5
) and reassemble facepiece in reverse order.
For facepieces only!
Miele** (by Miele & Cie. KG, Professional,
Germany)
®
• Ecolab Eltra
(7 g/l)*
®
• Ecolab Sekumatic
Decontamination + Disinfection:
• 20 minutes at 60 °C with Ecolab Eltra
• 5 minutes at 60 °C with Ecolab
®
Sekumatic
FDR
Disinfection:
• 20 minutes at 60 °C with Ecolab Eltra
• 5 minutes at 60 °C with Ecolab
®
Sekumatic
FDR
4 Disinfection
FDR (10 ml/l, 1%)*
®
®
19