ETC Installation Guide
ColorSource Spot jr v2.0/v3.0/v4.0
4. Press the Mode button to start the update process.
• The first time that you push an updated software version,
• The display alternates between
• The display blinks once to indicate that the update is complete.
5. Reconnect DMX In on the fixture.
Restore Factory Defaults
Press and hold the Mode button, Up button, and Down button
simultaneously for 5 seconds. The DMX start address will blink once to
confirm that defaults have been restored.
Error Codes
These error codes may display on the user interface.
•
CAL
with the color calibration. The fixture will need to be returned to
the ETC factory; contact your local dealer to set up a repair.
•
OtP
fixture has gone into over-temperature protection mode to avoid
damaging the fixture. Once the fixture has self-cooled, the error
will automatically clear. If the error does not clear, contact
ETC Technical Support (visit etcconnect.com/contactETC).
•
No App
upgraded fixtures have a software issue. Reload software to clear
the error. If the error persists, contact ETC Technical Support (visit
etcconnect.com/contactETC).
ColorSource Spot jr
additional required files must be copied before the update can
begin. The display alternates between
indicate the percentage complete while required data is
copied.
complete while updating the connected fixtures.
: Screen toggles between
: Screen toggles between
: Screen toggles between
Udt
CAL
Err
and
OtP
Err
and
no
and
Page 12 of 16
Udt
c:XX
and
and the percentage
to indicate a problem
to indicate that the
APP
to indicate that the
to
ETC
Need help?
Do you have a question about the ColorSource Spot jr v2.0 and is the answer not in the manual?
Questions and answers