ELECTRIC STARTING SYSTEM
EAS2DM1098
STARTING CIRCUIT CUT-OFF SYSTEM OPERATION (for YP125RA)
If the main switch is set to "ON" (switch circuit is closed), the starter motor can only operate if the fol-
lowing conditions are met:
• The brake lever is pulled to the handlebar (the brake switch is closed) and the sidestand is up (the
sidestand switch is closed).
The starting circuit cut-off relays 1 and 2 prevents the starter motor from operating when neither of
these conditions has been met. In this instance, the starting circuit cut-off relays 1 and 2 are open so
current cannot reach the starter motor. When at least one of the above conditions has been met, the
starting circuit cut-off relays 1 and 2 are closed and the engine can be started by pressing the start
switch " ".