TwinSAFE group outputs
Name
FB ERR
COM ERR
OUT ERR
5.3.8
Append a function block
The KL6904 TwinSAFE logic terminal features the following blocks: Emergency Stop, Machine Monitoring,
AND, OR, Decoupler, Operation Mode, etc.
A function block is added by right-clicking on the associated TwinSAFE function block list in the tree
structure and selecting Append Function Block in the dialog box with the left mouse button (see diagram).
Fig. 17: Add function block
The required function block can then be selected from the following window.
KL6904
Permitted type
TwinSAFE-Out
FB-In
Standard-Out
TwinSAFE-Out
FB-In
Standard-Out
TwinSAFE-Out
FB-In
Standard-Out
Version: 3.0.0
Description
TRUE:
At least one assigned function block has
an error
FALSE:
All assigned function blocks have no errors
TRUE:
At least one TwinSAFE connection of
TwinSAFE group has an error
FALSE:
All TwinSAFE connections of the
TwinSAFE group have no errors
TRUE:
At least one locally assigned output of the
TwinSAFE group has an error
FALSE:
All of the locally assigned outputs of the
TwinSAFE group have no errors
Operation
37