System description
3.1.2

Bus Terminals

Mechanical data
Material
Dimensions (W x H x D)
Mounting
Attachable by
Fig. 3: TwinSAFE Terminals
Connection technology
Wiring
Connection cross-section
Fieldbus connection
Power contacts
Current load
Rated voltage
16
Bus Terminal
polycarbonate, polyamide (PA6.6).
12 mm x 100 mm x 68 mm or 24 mm x 100 mm x 68 mm
on 35 mm mounting rail (EN 60715) with locking
double slot and key connection
Bus Terminal
©
cage Clamp
spring-loaded system
0.08 mm² ... 2.5 mm², stranded wire, solid wire
depending on fieldbus
up to 3 blade/spring contacts
10 A
depends on Bus Terminal type