BINARY VALUES

POINT SETPOINT
OBJECTNAME
BLOCK
10
No
CommunicationsStatus (D10)
12
No
LocalDehumidControl (D12)
20
No
AirflowOKforElecHeat (D20)
23
Yes
DisableLocalSetptSliderViaEMS
(D23)
57
No
TerminalFanDefined (D57)
58
No
LocalCO2Control (D58)
65
No
LocalStptSlider (D65)
78
No
FanCmdAnimation (D78)
97
No
CO2ControlRemote_Slave (D97)
100
No
Damper
Offline (D100)
122
No
PriAirModeEffCmd (D122)
123
No
PriAirStateEffCmd (D123)
125
No
FireStopEffCmd (D125)
127
No
DehumidControlRemote_Slave
(D127)
128
No
DamperStuck
CBV-2U4-3T ONLY
131
No
DampMaxManEff (D131)
132
No
DampMinManEff (D132)
133
No
DampAuxManEff (D133)
136
No
DampOpenManEff (D136)
137
No
DampCloseManEff (D137)
150
Yes
TABPriAirZero (D150)
160
Yes
CmdPriAirMode (D160)
161
Yes
CmdPriAirState (D161)
163
Yes
DampAuxMan (D163)
166
No
UI01DigitalStatusHost (D166)
169
No
LocalTempSensorFault (D169)
170
Yes
DO11RemoteCmd (D170)
171
Yes
DO12RemoteCmd (D171)
FanCoolMaxMan (D172)
172
Yes
173
Yes
FanDeadbandMan (D173)
©ABB 2022 All Rights Reserved.
Subject to change without notice
WWW.CYLON.COM
Appendix : List of CBV-2U4-3T(-N) points
DESCRIPTION
Communications with master controller
failure if
OfflineTimerEnaBACnet (D257)
is enabled
Enabled if local dehumidification
control has been configured
Enabled when airflow has proved for
electric heat. Applies to VAVs with no
fan or series fan
Disables the local setpoint slider
Enabled when controller has been
configured for a series or parallel fan
Enabled if local CO
control has been
2
configured
Enabled if local slide adjust has been
configured and is not disabled by point
DisableLocalSetptSliderViaEMS (D23)
Current fan command
CO
control source
2
Indicates bad communication for
internal damper MPBus (CBV-2U4-3T
only)
Current Primary Air Mode Command
Current Primary Air State Command
Primary Air Mode Fire Stop Command
Dehumidification Control Source
ON=Remote, OFF=Local
If after stuck damper delay (A20)
seconds the actual damper % is not
within +/- of stuck damper deadband
(A19) this value is true, otherwise it is
false.
Damper set to Max Flowrate Manual
Mode
Damper set to Min Flowrate Manual
Mode
Damper set to Heat Flowrate Manual
Mode
Damper set Full Open Manual Mode
Damper set Full Close Manual Mode
TAB Calibrate Zero Airflow
Primary Air Mode Command
Primary Air State Command
Damper Command to Heat Flowrate
Manual Mode
UI01 Digital Control value
If zone temperature has short or open
circuit, this point will be triggered
DO11 override on command
DO12 override on command
Fan Commanded to Max Cool Speed
Manual Mode
Fan Commanded to Min Speed Manual
Mode
ACTIVE
INACTIVE
DEFAULT VALUES
TEXT
TEXT
IMP STG.
STG.
On
Off
0
Enable
Disable
0
On
Off
0
On
Off
0
Enable
Disable
0
Enable
Disable
0
Enable
Disable
0
On
Off
0
Enable
Disable
0
On
Off
0
Enable
Disable
0
Heatin
Cooling
0
g
Enable
Disable
0
Enable
Disable
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
Enable
Disable
0
Heatin
Cooling
0
g
On
Off
0
On
Off
0
Alarm
Normal
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
MET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0