ABB CBV-2U4-3T User Manual page 70

Table of Contents

Advertisement

CBV-2U4-3T(-N) |
POINT SETPOINT
OBJECTNAME
BLOCK
241
No
UnoccHeatRequest (D241)
242
No
UnoccCoolRequest (D242)
251
Yes
Fusion_OvrReset (D251) with
Actuator
253
No
PriDamperOpenCmd (D253)
254
No
PriDamperCloseCmd (D254)
257
Yes
OfflineTimerEnaBACnet (D257)
284
No
DO11CmdDisplay (D284)
285
Yes
ParallelFanEnabPriAirHot (D285)
296
Yes
EnabDamperPosReset (D296)
297
Yes
FusionStatLockout (D297) with
Actuator
305
No
DO12CmdDisplay (D305)
306
No
DO13CmdDisplay (D305)
312
Yes
DO13RevAct (D312)
313
Yes
DO11RevAct (D313)
314
Yes
DO12RevAct (D314)
324
Yes
FusionStatLockout (D324) without
Actuator
335
Yes
Fusion_OvrReset (D335) without
Actuator
©ABB 2022 All Rights Reserved.
Subject to change without notice
WWW.CYLON.COM
Appendix : List of CBV-2U4-3T(-N) points
DESCRIPTION
Unoccupied heat request
Unoccupied cool request
When toggled, the FusionAir sensor will
reset all override timers. (FA Variants
only)
Primary Damper Open Command
Primary Damper Close Command
Enables offline timer test. When set to
on controller will be set to occupied
when loss of BACnet MS/TP
communication occurs
If DO11 is used in strategy this point will
display on when DO 11 is commanded
on
When this point is enabled, parallel fan
will be allowed to run when primary air
state is hot and there is a call for heat
By default, when VAV is in unoccupied
mode and there is less than 10 CFM the
damper will drive shut for 100 seconds
to zero out damper position calculation
When set to ON, temperature
adjustment will be disabled on the
FusionAir sensor. When set to OFF,
temperature adjustment is enabled on
the FusionAir sensor. (FA Variants only)
If DO12 is used in strategy this point
will display on when DO 12 is
commanded on
If DO13 is used in strategy this point
will display on when DO 13 is
commanded on
When this point is enabled, DO13 will be
set for reverse acting
When this point is enabled, DO11 will be
set for reverse acting
When this point is enabled, DO12 will be
set for reverse acting
When set to ON, temperature
adjustment will be disabled on the
FusionAir sensor. When set to OFF,
temperature adjustment is enabled on
the FusionAir sensor. (FA Variants only)
When toggled, the FusionAir sensor will
reset all override timers. (FA Variants
only)
ACTIVE
INACTIVE
DEFAULT VALUES
TEXT
TEXT
IMP STG.
STG.
On
Off
0
On
Off
0
On
Off
On
Off
0
On
Off
0
Enable
Disable
0
On
Off
0
Enable
Disable
0
Enable
Disable
1
On
Off
On
Off
0
On
Off
0
Enable
Disable
0
Enable
Disable
0
Enable
Disable
0
On
Off
On
Off
MET
0
0
0
0
0
0
0
1
0
0
0
0
0
70