ABB CBV-2U4-3T User Manual page 63

Table of Contents

Advertisement

CBV-2U4-3T(-N) |
POINT SETPOINT
OBJECTNAME
BLOCK
79
No
LocalRemoteSlaveDehumidCalc (A79)
80
Yes
Group1TABCode (A80)
84
Yes
OutputConfigC_Bsbd (A84)
85
Yes
Group2TABCode (A85)
86
No
StptSliderEffOccOffset (A86)
87
Yes
Group3TABCode (A87)
88
No
EffGroupAddress (A88)
90
Yes
Group0OccCode (A90)
91
Yes
Group1OccCode (A91)
92
Yes
Group2OccCode (A92)
93
Yes
GroupAddress (A93)
100
Yes
Group3OccCode (A100)
103
No
Fusion_ZoneTemp (A103) with Actuator
105
No
ZeroOffsetCalc
106
No
Fusion_ZoneHumidity(A106) with
Actuator
109
No
Fusion_CO2 (A109) with Actuator
112
Yes
ElecHeatCFMTestTime (A112)
113
No
Fusion_CO2 (A113) without Actuator
120
Yes
UI03_10KSensorCal (A120)
122
No
UI03_10KSensorHost (A122)
125
No
TABPriAirMaxHtgStpt
140
No
TABPriAirEffMaxStpt (A140)
141
Yes
heatStateOnStpt (A141)
143
Yes
AO14RemoteCmd (A143)
153
Yes
TabPriAirMinHtgStpt (A153)
154
Yes
TabFanHtgMinStpt (A154)
155
No
AO14DisplayPos (A155)
157
Yes
CustomClosedVX10_AO15 (A157)
168
Yes
Remote_SlaveTemp (A168)
172
No
TotalHeatingStagesDefined (A172)
©ABB 2022 All Rights Reserved.
Subject to change without notice
WWW.CYLON.COM
Appendix : List of CBV-2U4-3T(-N) points
DESCRIPTION
Current dehumidification command
0 ... 100%
Group 1 TAB code
VAV box configuration setpoint
Group 2 TAB code
Current slider setpoint offset
Group 3 TAB code
Current group address
Group 0 command used to put VAV box
in multiple modes of operation. This
point supports priority array.
Group 1 command used to put VAV box
in multiple modes of operation. This
point supports priority array.
Group 2 command used to put VAV box
in multiple modes of operation. This
point supports priority array.
Point used to set the group address
Group 3 command used to put VAV
box in multiple modes of operation.
This point supports priority array.
The space temperature as detected
by the FusionAir sensor. (FA Variants
only)
Measured offset after air flow sensor
has been zeroed
The space humidity as detected by
the FusionAir sensor. (FA Variants
only)
The space CO2 as detected by the
FusionAir sensor. (FA Variants only)
Amount of seconds current Flowrate
needs to be above calculated
Flowrate setpoint before enabling
electric heat. Only applicable for VAV
boxes configured for no fan or series
fan
The space CO₂ as detected by the
FusionAir sensor. (FA Variants only)
UI03 sensor calibration offset
Current UI03 sensor reading with
calibration offset
Maximum heating CFM Setpoint
Current effective maximum Flowrate
setpoint
Temperature setpoint for setting
Primary Air State to hot when VAV
box has been configured for local
auto change over.
AO14 remote command
Primary air max heating Flowrate
setpoint. This point supports priority
array.
Minimum heating variable speed fan
command setpoint
AO14 display value 0 ... 100%
AO15 Close Value Custom = Volts X 10
Remote control temperature written
to from master controller
Amount of stages of heat defined
UNITS AND DEFAULT VALUES
IMPERIAL STG.
METRIC STG.
0
%
0
%
0
no-units
0
no-units
no-units
no-units
128
128
0
no-units
0
no-units
0
°F
0
°C
no-units
no-units
0
0
0
no-units
0
no-units
no-units
no-units
1
1
no-units
no-units
1
1
1
no-units
1
no-units
0
no-units
0
no-units
no-units
no-units
1
1
0
°F
0
°C
0
no-units
0
no-units
0
%rh
0
%rh
0
ppm
0
ppm
60
sec
60
sec
0
ppm
0
ppm
0
°F
0
°c
0
°F
0
°C
0
CFM
0
l/sec
0
CFM
0
l/sec
80
°F
27
°c
0
%
0
%
50
CFM
25
l/sec
0
%
0
%
0
%
0
%
0
%
0
%
55
°F
21
°c
no-units
no-units
0
0
63