CBV-2U4-3T(-N) |
POINT SETPOINT
OBJECTNAME
BLOCK
174
Yes
FanHeatMaxMan (D174)
175
Yes
FanStandbyMan (D175)
DO13RemoteCmd (D177)
177
Yes
178
Yes
EnableManualHeatCmd (D178)
179
Yes
EnableManualCoolCmd (D179)
180
No
HeatModeSts
181
No
CoolModeSts
184
Yes
OccCmd (D184)
185
Yes
StandbyCmd (D185)
OccModeSts (D186)
186
No
187
No
StandbyModeSts (D187)
188
No
OccSensorEffCmdOnBoardSwitch
(D188)
191
Yes
DampOpenMan (D191)
192
Yes
DampCloseMan (D192)
193
Yes
DampMaxMan (D193)
194
Yes
DampMinMan (D194)
199
Yes
FireStopCmd (D199)
KFactSelect (D204)
204
Yes
208
No
LoadShedEffCmd (D208)
210
Yes
FanHeatMinMan (D210)
211
Yes
LoadShedEnable (D211)
213
Yes
Purge (D213)
222
No
OverrideStatus_Outputs (D222)
223
No
ManualStatus_Application (D223)
224
No
OverrideStatus_Inputs (D224)
225
Yes
DamperAdaption(D225)
CBV-2U4-3T ONLY
226
PurgeEffCmd (D226)
No
230
Yes
DampReverse (D230)
231
Yes
EnaUnoccCool (D231)
232
No
IO_Application_Status (D232)
235
No
UI04DigitalStatusHost (D235)
©ABB 2022 All Rights Reserved.
Subject to change without notice
WWW.CYLON.COM
Appendix : List of CBV-2U4-3T(-N) points
DESCRIPTION
Fan Commanded to Max Heat Speed
Manual Mode
Fan Commanded to Standby Speed
Manual Mode
DO13 override on command
Manual Heat Enable Command
Manual Cool Enable Command
Heat mode status
Cool mode status
Occupancy command
Standby command
Occupancy mode status
Standby mode status
Occupancy effective command from
push button override or motion sensor
Set Damper Full Open Manual Mode
Set Damper Full Close Manual Mode
Damper set to Max Flowrate Manual
Mode
Damper set to Min Flowrate Manual
Mode
Damper set to Fire Stop Cmd
True will allow measured flow to be
entered at (A218), False will allow
factory K-factor to be entered at (A218)
Load Shed Enable Effective Command
Fan Commanded to Min Heat Speed
Manual Mode
Load Shed Enable Command
Box damper will be overridden open.
If any outputs have been overridden
this point will be on
If any TAB manual mode override points
have been set to on this point will be on
If any inputs have been overridden this
point will be
ON
When adaptation is selected, the
actuator will drive one full cycle to its
mechanical end-stop, and when it
reaches that point the actuator's
working range will be adapted to the
actual mechanical angle of rotation. To
initiate this process, toggle point D225
On, then toggle it Off.
If commanded to Purge mode this point
will be on
Reverses damper action
0 = CW open, CCW close
1 = CW close, CCW open
This point enables unoccupied cooling
If any input, outputs, or manual status
application mode is on, this point is on
UI04 digital status host
ACTIVE
INACTIVE
DEFAULT VALUES
TEXT
TEXT
IMP STG.
STG.
On
Off
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
Non
Occ
1
Occ
On
Off
0
Non
Occ
0
Occ
On
Off
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
Enable
Disable
0
On
Off
0
Enable
Disable
0
On
Off
0
Enable
Disable
0
Enable
Disable
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
On
Off
0
Enable
Disable
1
On
Off
0
On
Off
0
MET
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbv-2u4-3t-n

Table of Contents