POST Error Messages
continued
Code
1785
Slot 1 Drive Array not configured
(proceeded by one of the following:)
1. Run Compaq Array Configuration Utility.
2. No drives detected.
3. Array Accelerator Memory Size Increased.
4. External cable(s) Attached to Wrong SCSI
Port Connector(s).
5. Drive positions cannot be changed during
Capacity Expansion.
6. Drive positions appear to have changed.
7. Configuration information indicates drive
positions beyond the capability of this
controller. This may be due to drive
movement from a controller that supports
more drives than the current controller.
8. Configuration information indicates drives
were configured on a controller with a newer
firmware version.
Slot x Drive Array Recovery Needed. The
1786
following SCSI drive(s) need Automatic Data
Recovery: SCSI Port (y): SCSI ID (x)
Select F1 to continue with recovery of data to
drive .
Select F2 to continue without recovery of data
to drive .
Or
Slot x Drive Array Recovery Needed. The
following SCSI drive(s) need Automatic Data
Recovery: SCSI Port (y): SCSI ID (x)
Select F1 to retry Automatic Data Recovery to
drive .
Select F2 to continue without starting
Automatic Data Recovery data to drive .
Writer: Rickard Project: Compaq Smart Array 3200 Controller Reference Guide Comments: 340862-002
Meaning
File Name: P-APPI.DOC Last Saved On: 12/7/98 9:35 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Recommended Action
1. Run the Compaq Array Configuration Utility.
2. Turn off the system and check SCSI cable
connections to make sure drives are properly
attached.
3. Run the Compaq System Configuration Utility.
4. Turn system power OFF and swap SCSI port
connectors to prevent data loss.
5-6. Run Array Diagnostic Utility if previous
positions are unknown. Then turn system power
OFF and move drives to their original positions.
7. To avoid data loss, turn the system power
OFF and reattach drives to the original
controller.
8. To avoid data loss, reattach drives to original
controller or upgrade controller firmware to the
version on the original controller using Options
ROMPaq.
Press F1 to resume.
The message normally appears when a drive
was replaced in a fault-tolerant configuration
with system power off. In this case, press F1 to
start the automatic data recovery process.
The "previously aborted" version of the 1786
POST message will appear if the previous
rebuild attempt was aborted for any reason. Run
Array Diagnostic Utility (ADU) for more
information. If the replacement drive was failed,
try using another replacement drive. If rebuild
was aborted due to a read error from another
physical drive in the array, you'll need to back
up all readable data on the array, run
Diagnostics Surface Analysis, and then restore
your data.