I-8 POST Error Messages
POST Error Messages
Code
1779
Slot x Drive Array - Replacement drive(s)
detected OR previously failed drive(s) now
appear to be operational:
Port (y): SCSI ID ( x ): Restore data from backup
if replacement drive x has been installed.
1783
Slot x Drive Array Controller Failure.
1784
Slot x Drive Array Drive Failure. The following
SCSI drive(s) should be replaced: SCSI Port (y)
SCSI ID ( x )
Writer: Rickard Project: Compaq Smart Array 3200 Controller Reference Guide Comments: 340862-002
continued
Meaning
File Name: P-APPI.DOC Last Saved On: 12/7/98 9:35 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Recommended Action
If this message appears and drive x (identified
by its SCSI ID) has not been replaced, this
indicates an intermittent drive failure. This
message also appears once, immediately
following drive replacement before data is
restored from backup.
If this message appears immediately following a
ROM installation, the ROM is defective or not
installed properly. Check to see if the Array
Accelerator board is attached properly. Verify
that the array controller is firmly inserted in its
slot. Try upgrading the Systems ROMs.
Otherwise, replace the Smart Array Controller.
Check for loose cables. Replace defective drive
x and/or cable(s).
Continued