Technical Specifications - DELTA DORE Tybox 5300 Quick Start Manual

Hide thumbs Also See for Tybox 5300:
Table of Contents

Advertisement

To verify the time base settings of each receiver:
mode
1
> 3s
❶ From the CF08 menu, press + or -.
The screen will display "--" (several
receivers have different settings).
NOTE: During this step, do not
press + or -.

8. Technical specifications

TYBOX 5300 transmitter
• Power supply using 2 batteries:
2x1.5V Alkaline - Type LR03-AAA
• Class III insulation
• X3D transmission frequency: 868.7 MHz to 869.2 MHz
• Maximum wireless power < 10 mW
• Category II receiver
• Wireless range of 300 metres outside, varies depending on
the associated equipment (the range can vary depending
on the installation conditions and the electromagnetic
environment).
• Wall-mounted or on base
• Dimensions: 80 x 84 x 21 mm
• Protection Class: IP 20
• Installation in an environment with normal pollution levels
• Storage temperature: -10°C /+70°C
• Operating temperature from -10°C/+40°C
mode
2
❷ Press mode for 3 seconds until
the time base value is displayed.
The LED on the respective receiver
flashes.
mode
3
❸ Press mode to switch to the next
receiver.
The LED on the concerned receiver
flashes and the value of its time
base is displayed.
RF 6050+ receiver
• Power supply 230 V ~, 50 Hz
• Consumption: max. 0.8 W
• Class II insulation
• Contact output 5 A max., 230V ~
• Cable diameter 7mm +/- 0.4mm
- cable length: 1.25 m
• Type 1.C automated action
• Dimensions: 54 x 140 x 25 mm
• X3D transmission frequency: 868.7 MHz to 869.2 MHz
• Maximum wireless power < 10 mW
• Category II receiver
• Wireless remote control device
• Wireless range of 300 metres outside, varies depending on
the associated equipment (the range can vary depending
on the installation conditions and the electromagnetic
environment).
• Protection rating: IP 44
- with the supplied cable,
- vertical positioning of the product.
• Storage temperature: -10°C /+70°C
• Operating temperature: -10°C/+60°C
• Ball test temperature: 75°C (Housing),
• Rated impulse voltage: 2,500V
mode
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tybox 5101

Table of Contents