Table Of Contents; Installing The Room Unit; Room Unit; Technical Unit - DELTA DORE DELTA 200 Installation Manual

Outdoor-temperature-driven controller for hot water heating
Hide thumbs Also See for DELTA 200:
Table of Contents

Advertisement

Contents
Installing the room unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Room unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Technical unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installing the sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Water temperature sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Outdoor sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Determining the type of installation . . . . . . . . . . . . . . . . . . . . . . . . 6
Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Technical characteristics

Technical unit

• 230V, 50 Hz power supply, ±10%
• Class I insulation
• Consumption: 4 VA
• 1 outdoor sensor input
• 2 feed (zone 1) and return (zone 2) sensor
inputs
• 2 circulator control outputs (zone 1 and
zone 2): 2A, 230V
• 1 boiler control output, 2A dry contact (do
not supply mains power)
• 1 mixer valve control output: 2 2A, 24V or
230V operating contacts that open and
close the valve (zone 1)
• Bus connection with the room unit: insulated
1.52 electric cable, max. length 50 m
• Automatic action: 1.C
• Storage temperature: -10°C to +70°C
• Operating temperature:
0°C to +40°C
• Dimensions: 80 x 230 x 65 mm
• Fire rating: 5V
• Circulator anti-seizing function: it switches
the circulator on for 3 seconds if the circula-
tor has not operated in the previous 24
hours (useful when the heating is off).

Room unit

• Power supply by bus, 12 to 22V voltage
• Class III insulation
• Clock backup during mains power failure: 2
hours (by capacitor)
• Storage temperature: -10°C to +70°C
• Operating temperature: 0°C to +40°C
• Dimensions: LxHxD = 82 x 94 x 53 mm
• Protection index: IP 30
• Fire rating: Vo
- 2 -

Installing the room unit

Choosing a location
Since the temperature measurement sensor is inside the unit, you must
install the thermostat flush-mounting box:
- in zone 1 (main room) only,
- on an accessible wall at a height of 1.50 m,
- away from heat sources (fireplaces, sunlight) and draughts (windows,
doors).
IMPORTANT: Do not install the thermostat on a wall in contact with the out-
doors or with an unheated room (e.g. garage, etc.).
The sleeve output in the flush-mounting box must be plugged (with mastic)
in order to avoid unwanted air movements that would cause the sensor rea-
ding to be inaccurate.
approx. 1.5 m
Min. 20 cm
- 3 -