26 Chapter 1 Installing the Contivity 1740 chassis

Mounting the chassis in the equipment rack

Nortel Networks recommends that two people install the chassis in the rack.
To install the Contivity 1740 in the equipment rack:
1
Set the Contivity 1740 on the rack-mount shelf.
2
Remove the front bezel from the Contivity 1740
a

Figure 5 Removing the front bezel

b Grip the two handles and firmly pull the bezel toward you to unsnap it
317086-B Rev 00
Using the Phillips screwdriver, turn each of the 2 screws on the front bezel
a quarter turn counterclockwise.
from the chassis.
Caution: Do not use the piece with the Nortel Networks logo and the
LEDs as a handle.
The first few times that you remove the front bezel, it may be somewhat
difficult to remove because the ball studs and socket clips are new.
(Figure
5).
CS260015D