Allen-Bradley Rockwell Automation 857 User Manual page 34

Hide thumbs Also See for Rockwell Automation 857:
Table of Contents

Advertisement

2-18
Local Panel User Interface
Operating measures (cont.)
857-UM001A-EN-P – July 2009
Table 2.3 – Measured Values (cont.)
Value
Menu/Submenu
E+.nn
E/DECIMAL COUNT
Eq.nn
E/DECIMAL COUNT
E-.nn
E/DECIMAL COUNT
Ewrap
E/DECIMAL COUNT
E+
E/E-PULSE SIZES
Eq+
E/E-PULSE SIZES
E-
E/E-PULSE SIZES
Eq-
E/E-PULSE SIZES
E+
E/E-PULSE DURATION
Eq+
E/E-PULSE DURATION
E-
E/E-PULSE DURATION
Eq-
E/E-PULSE DURATION
E+
E/E-pulse TEST
Eq+
E/E-pulse TEST
E-
E/E-pulse TEST
Eq-
E/E-pulse TEST
IL1
I/PHASE CURRENTS
IL2
I/PHASE CURRENTS
IL3
I/PHASE CURRENTS
IL1da
I/PHASE CURRENTS
IL2da
I/PHASE CURRENTS
IL3da
I/PHASE CURRENTS
Io
I/SYMMETRIC CURRENTS
Io2
I/SYMMETRIC CURRENTS
IoC
I/SYMMETRIC CURRENTS
I1
I/SYMMETRIC CURRENTS
I2
I/SYMMETRIC CURRENTS
I2/I1
I/SYMMETRIC CURRENTS
THDIL
I/HARM. DISTORTION
THDIL1
I/HARM. DISTORTION
THDIL2
I/HARM. DISTORTION
THDIL3
I/HARM. DISTORTION
Diagram
I/HARMONICS of IL1
Diagram
I/HARMONICS of IL2
Diagram
I/HARMONICS of IL3
Uline
U/LINE VOLTAGES
U12
U/LINE VOLTAGES
U23
U/LINE VOLTAGES
U31
U/LINE VOLTAGES
UL
U(PHASE VOLTAGES
Description
Decimals of exported energy [ ]
Decimals of reactive energy [ ]
Decimals of imported energy [ ]
Energy control
Pulse size of exported energy [kWh]
Pulse size of exported reactive energy [kvar]
Pulse size of imported energy [kWh]
Pulse duration of imported reactive energy [ms]
Pulse duration of exported energy [ms]
Pulse duration of exported reactive energy [ms]
Pulse duration of imported energy [ms]
Pulse duration of imported reactive energy [ms]
Test the exported energy pulse [ ]
Test the exported reactive energy [ ]
Test the imported energy [ ]
Test the imported reactive energy [ ]
Phase current IL1 [A]
Phase current IL2 [A]
Phase current IL3 [A]
15 min average for IL1 [A]
15 min average for IL2 [A]
15 min average for IL3 [A]
Primary value of zero sequence/ residual current
Io [A]
Primary value of zero-sequence/residual current
Io2 [A]
Calculated Io [A]
Positive sequence current [A]
Negative sequence current [A]
Negative sequence current related to positive
sequence current (for unbalance protection) [%]
Total harmonic distortion of the mean value of
phase currents [%]
Total harmonic distortion of phase current IL1 [%]
Total harmonic distortion of phase current IL2 [%]
Total harmonic distortion of phase current IL3 [%]
Harmonics of phase current IL1 [%]
(See Figure 2.16)
Harmonics of phase current IL2 [%]
(See Figure 2.16)
Harmonics of phase current IL3 [%]
(See Figure 2.16)
Average value for the three line voltages [V]
Phase-to-phase voltage U12 [V]
Phase-to-phase voltage U23 [V]
Phase-to-phase voltage U31 [V]
Average for the three phase voltages [V]

Advertisement

Table of Contents
loading

Table of Contents