gefran ILI Series Original Operating Instructions page 29

Pressure sensors for high temperature io-link impact
Table of Contents

Advertisement

1) the IL transducer has analog output and is power supplied through an IO-Link master; IO-Link communication can be on or not;
the transducer detects the pressure and gives in output an analog electrical value proportional to the pressure itself; SRP/CS
compares the signal with its internal alarm threshold: if the threshold is exceeded the SRP/CS will stop the pressure generation
systems.
2) the IL transducer has analog output and is powered directly through the SRP/CS; the transducer detects the pressure and
gives in output an analog electrical value proportional to the pressure itself; SRP/CS compares the signal with its internal alarm
threshold: if the threshold is exceeded the SRP/CS will stop the pressure generation systems.
SRP/CS
Analog
input
3) the IL transducer has relay output and is power supplied through an IO-Link master; IO-Link communication can be on or not; the
sensor detects the pressure and compares it with a determined threshold; if the threshold is exceeded, the relay will open; the
relay output is interfaced with an enable input of the pressure generating system motor drive; when the threshold is exceeded,
the open state of the relay stops the pressure generating systems.
80618_MAN_IO-LINK IMPACT_12-2019_ENG
IO-link master
S+
V-
SRP/CS
Analog
input
V+
S+
V-
O
IO-link master
RL1
RL2
Motor drive
IL transducer
Y splitter
O
Figure 5
IL transducer
Figure 6
IL transducer
Y splitter
Pressure
generation
system
Figure 7
29