gefran ILI Series Original Operating Instructions page 14

Pressure sensors for high temperature io-link impact
Table of Contents

Advertisement

7.1. IO-Link Information
Table 2
IO-Link information
Port Class
Baud rate
IO-Link version (1)
Profile
Process data input length
Process output data length
Min Cycle Time
SIO mode
ISDU
Data storage
Compliant to IO-Link interface specification v1.1.2 (Jul13)
7.2. SIO mode and IO-Link mode
The IL transducer supports both SIO mode and IO-Link mode:
• In SIO mode the transducer behaves like a digital sensor: on pin 4 and 2 of M12 connector two digital thresholds are available
and programmable (replicating the same behavior configured for SSCs, see par 7.6)
• In IO-Link mode the transducer communicates with a standard IO-Link master on pin 4 of M12 connector
7.3. Process Data mapping (IO-Link)
The IL transducer offers two possible mappings of Input Data, according to ordering code (if temperature measurement is available or not).
• Standard version
15...2
Pressure measurement
• Integrated Temperature version
31...16
Temperature measurement
Where:
• Temperature measurement is the value of temperature taken at the tip of transducer (behind the membrane), given with 0,1°C
resolution.
• Pressure measurement is the value of pressure given in the unit selected according to ordering code and decimal digits according
to the following table:
• SSC1: switching signal 1 is a on/off bit changing its value according to the overtaking of a pressure threshold that can be
programmed by the user; several configurations are available (see par.7.6)
• SSC2: switching signal 2 is a on/off bit changing its value according to the overtaking of a pressure threshold that can be
programmed by the user; several configurations are available (see par.7.6)
14
7. COMMAND MODES
A
COM2 (38.4 kB)
1.1
Generic Smart Sensor
Standard = 2 Bytes (Pressure + SSCs)
T version = 4 Bytes (Temperature + Pressure + SSCs)
0
Standard = 2,7 ms
T version = 3,5 ms
Supported
Supported
Supported
15...2
Pressure measurement
Measuring range [bar]
17<= bar <=100
100< bar <=1000
Measuring range [psi]
250<= psi <=1450
1450 < psi <=15000
1
SSC2
1
SSC2
Decimal Digits
2
1
Decimal Digits
1
0
80618_MAN_IO-LINK IMPACT_12-2019_ENG
0
SSC1
0
SSC1