gefran ILI Series Original Operating Instructions page 20

Pressure sensors for high temperature io-link impact
Table of Contents

Advertisement

• Device parameters – Extended Index
Sub
Index
Object Name
Index
0x0100
0x00
Calibration Date
Cal Mode Enable
0x0101
0x00
Relay Status*
0x0102
0x00
0x0103
0x00
Lin error (%FS)
0x0104
0x00
Zero calibration
0x0105
0x00
Span calibration
0x0106
0x00
Relay Activation Threshold*
0x0107
0x00
PressurePeaksCounterTh
0x0108
0x00
UseAutozeroCorrection
0x0109
0x00
RelayOutEnabled*
0x010A
0x00
PressureDataUnit
0x010B
0x00
FullScaleValue
0x010C
0x00
OperatingTimeCounter
OperatingTimeInPressureCounter
0x010D
0x00
0x010E
0x00
PressurePeaksCounter
0x010F
0x00
PressureMaxValue
0x0111
0x00
TemperaturePeaksCounter***
0x0112
0x00
TemperatureMaxValue***
0x0114
0x00
TemperaturePeaksCounterTh
0x0115
0x00
Special Execution Tag
0x0116
0x00
AutozeroCorrection
Lower Range Value (LRV)**
0x0117
0x00
20
Access
Length
Data
(Bytes)
Type
U
M
S
RO RO RO 8
String
RO R/W R/W 1
Boolean
RO RO RO 1
Boolean
RO RO RO 1
Int8
RO RO RO 1
Uint16
RO RO RO 1
Uint16
RO RO RO 1
Uint8
RO R/W R/W 1
Uint16
RO R/W R/W 1
Boolean
RO RO RO 1
Boolean
RO R/W R/W 1
Uint8
RO RO RO 2
Uint16
RO RO RO 2
UInt32
RO RO RO 2
UInt32
RO RO RO 2
UInt32
RO RO RO 2
UInt16
RO RO RO 2
UInt32
RO RO RO 2
Int16
RO RO RO 2
Int16
RO RO RO
String
RO RO RO 2
Int16
RO RO RO 2
UInt16
Value
Value
Gradient
(example)
Range
20190825
-
0: false
(default)
0...255
-
1...255:
true
0: Opened
1...255:
0...255
-
Closed
(default)
25
1...100
0,01
According
to MU
0
0...65535
See
Table 10
According
to MU
FS
0...65535
See
Table 10
80
10...100
1
1000
0...120%FS
1
0: off
1...255: on
0...255
-
(default)
0: Relay
output
disabled
1...255:
0...255
-
Relay
output
enabled
0x00: bar
0x01: psi
0...2
-
0x02: MPa
According
to MU
FS
0...FS
See
Table 10
0
0...4294967295 0,1
0
0...4294967295 0,1
0
0...4294967295 1
According
to MU
0
0...65535
See
Table 10
0
0...4294967295 1
1000
-32768...32767 0,1
-400...max
2500
0,1
(Temp Range)
1AA
-
-
According
to MU
0
-32768...32767
See
Table 10
According
to MU
0
0
See
Table 10
80618_MAN_IO-LINK IMPACT_12-2019_ENG
Offset Unit Description
Calibration date (yyyym-
-
-
mdd)
Enable/Disable the Cali-
-
-
bration function
Opened/Closed state of
-
-
the relay
Linearity error at factory
0
%
in %FS
Zero calibration value at
0
MU
factory in MU
Span calibration value at
0
MU
factory in MU
Threshold of relay opening
0
%
in %FS
Pressure peaks counter
0
MU
threshold in MU
Enable/disable autozero
-
-
correction
Defines if the transducer
has Relay output (enabled)
-
-
or not (disabled)
Measure Unit used for
pressure expressed
-
-
parameters.
IT DOES NOT AFFECT
PROCESS DATA
Factory full scale value,
0
MU
expresses in MU
Operating hours from first
power on, stored in non
0
h
volatile memory
Operating hours since
Pressure > 0,
0
h
stored in non volatile
memory
Count of times pressure
0
-
goes above PeakPres-
sureThreshold
Max value registered from
0
MU
last power on, stored in
non volatile memory
Count of times pressure
0
-
goes above PeakTempera-
tureThreshold
Max value registered from
0
°C
last power on, stored in
non volatile memory
Threshold of temperature
0
°C
peaks counter
String for special execution
-
-
versions
Actual zero Offset value.
0
MU
Useful to monitor the "zero
drifting" in time.
Rangeability functionality,
-
MU
specifies the initial value of
range for Analog output