gefran ILI Series Original Operating Instructions page 17

Pressure sensors for high temperature io-link impact
Table of Contents

Advertisement

Table 6
Error and Warnings in Detailed Device Status
Event Code
Event Type
-
-
-
-
-
-
0x5000
Error
0x8C10
Warning
0x8C30
Warning
0x5100
Error
0x5100
Error
0x5100
Error
0x8CA0
Error
0x4210
Error
0x8C00
Error
0x8CA5
Error
0x8CA6
Error
0x8CA7
Error
0x18A4
Error
0x8CA1
Warning
0x8CA2
Warning
0x8CA3
Warning
0x8CA4
Error
Table 7
Other Events
Event Code
Event Type
0x8DFD
Error
0x8DFE
Warning
0x8DFF
Notification
0x189C
Notification
0x189D
Notification
0x189E
Notification
0x189F
Notification
0x18A0
Warning
0x18A1
Notification
80618_MAN_IO-LINK IMPACT_12-2019_ENG
Device Status
Possible failure
Power supply cable
-
broken
-
Device not connected
-
Broken Power supply
Broken primary element
Failure
or not connected primary
element
Pressure above 150%
of Span respect to
Out of Specification
factory zero at room
temperature
Pressure below
-50% of Span respect
Out of Specification
to factory zero at room
temperature
Failure
Overvoltage
Failure
Undervoltage
Out of specification Voltage variations
Error in program
Failure
sequence
Electronics overtem-
Out of specification
perature
Failure
Error in input stage
Failure
Error in RAM Memory
Failure
Error in ROM Memory
Failure
Error in CPU
The Relay did not
Failure
open/close when
required
Not Functional Safety Related
Maintenance
Zero drift excessive
required
Process temperature
Out of specification
over limit allowed
Process temperature
Out of specification
below -30°C
Process temperature
Failure
sensor broken
Device Status Description
Failure
Test event type "Error"
OK
Test event type "Warning"
OK
Test event type "Notification"
OK
event for Autozero command successfully completed
OK
event for Autozero command failed due to value (autozero) out of range
OK
event for Autozero command failed due to function temporarily not available
OK
event for Autozero command reset
OK
event for Relay opened
OK
event for Relay Threshold Changed, required confirmation*
Output behavior
IO-Link
Relay
Pressure value
Functional Safety Related
-
Open
-
Open
-
Open
16000
Open
16000
Open
16000
Open
16000
Open
16000
Open
16000
Open
16000
Open
16000
Open
16000
Open
16000
Open
16000
Open
16000
Open
16000
-
-
-
-
-
-
-
Temperature =
-
10000
Reset Mode
Analog
LOW
Remove failure
LOW
Remove failure
LOW
Remove failure
Send device to factory
HIGH
for repair
Switch off and on; if error
HIGH
persists send to factory
for repair
Switch off and on; if error
HIGH
persists send to factory
for repair
Switch off and on; if error
LOW
persists send to factory
for repair
Switch off and on; if error
LOW
persists send to factory
for repair
Switch off and on; if error
LOW
persists send to factory
for repair
Switch off and on; if error
LOW
persists send to factory
for repair
Switch off and on (leave
temperature cool down);
LOW
if error persists send to
factory for repair
Switch off and on; if error
LOW
persists send to factory
for repair
Switch off and on; if error
LOW
persists send to factory
for repair
Switch off and on; if error
LOW
persists send to factory
for repair
Switch off and on; if error
LOW
persists send to factory
for repair
Switch off and on; if error
-
persists send to factory
for repair
Send device to factory for
-
maintenance
Switch off and on (leave
temperature cool down);
-
if error persists send to
factory for repair
Switch off and on (leave
temperature increase);
-
if error persists send to
factory for repair
Send device to factory
-
for repair
Note
Note
Valid for SIL 2 /
PL d Diagnostic
Valid for SIL 2 /
PL d Diagnostic
Valid for SIL 2 /
PL d Diagnostic
Only for SIL 2
/ PL d certified
transducer
Only for SIL 2
/ PL d certified
transducer
Only for SIL2/
PLd certified
transducer
Only for SIL 2
/ PL d certified
transducer
Only for SIL 2 /
PL d
Relay version
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ili0Ili1

Table of Contents