MELT IMPACT PRESSURE TRANSDUCERS
ILI series
Table 1
Accuracy (1)
Thermal drift in compesated range:
Zero / Calibration / Sensibility
Measuring ranges
Maximum overpressure (without degrading performances)
Measurement principle
Power supply
Maximum current absorption
Zero offset
Zero adjustment
Communication interface
Min Cycle time
IO-Link version
Transmission type
Profile
SIO mode
Required class for Master port
Pressure process data resolution
Temperature process data resolution
Analog output resolution
Rangeability
Calibration signal
Reverse polarity protection on power supply
Compensated temperature range (housing)
Operating temperature range (housing)
Storage temperature range (housing)
Diaphragm maximum temperature
Zero drift on process temp. 20 to 350°C
Span drift on process temp. 20 to 350°C
Integral temperature (optional)
Standard material in contact with process medium
Protection degree (5 pole female connector)
Insulation resistance (at 50Vdc)
Electromagnetic compatibility – Emission
Electromagnetic compatibility – Immunity
FS = Full scale output :
(1) BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity, Hysteresis and Repeatability (according to IEC 62828-2).
Sensors are manufactured in compliance with:
- EMC compatibility directive
- RoHS directive
- Machinery directive
Electrical installation requirements and Conformity certificate are available on our web site: www.gefran.com
6
3. TECHNICAL DATA
H <±0.25%FS (100...1000 bar)
M <±0.5%FS (10...1000 bar)
< 0.02% FS/°C
0...10 to 0...1200 bar
0...150 to 0...15000 psi
1.5 x FS (up to 1200 bar/ 17400 psi max)
Piezoresistive
18...30 Vdc
1W (1,2W with optional relay)
< ± 0.25% FS
"Autozero" function
IO-Link
2,7 ms (2 bytes PDI)
3,5 ms (4 bytes PDI)
1.1
COM2 (38.4 kB)
Smart Sensor Generic Profile
Yes
A
14 bit
16 bit
16 bit
3:1 (Analog output option)
80% FS
YES
0...+85°C
-30...+85°C
-40...+125°C
23...350 °C / 660 °F
< ± 1.2%FS
< ± 1%FS
Accuracy ± 2 °C
Diaphragm:
• 15-5PH with GTP+ coating
Stem:
• 17-4 PH
IP65 with suitable mating connector
>1000 Mohm
EN 61326-1
EN 61326-2-3
EN61326-3-1
EN 61326-1
EN 61326-2-3
EN61326-3-1
80618_MAN_IO-LINK IMPACT_12-2019_ENG