gefran ILI Series Original Operating Instructions page 13

Pressure sensors for high temperature io-link impact
Table of Contents

Advertisement

Please see below a couple of possible configurations:
Conf 1
IO-link standard master
SRP/CS
(Relay or
analog
input)
Conf 2
IO-link hybrid master, acts as SRP/CS (IO-link master + Safety input, Relay only)
*Y splitter is available on catalog in order to separate standard signal from safety signals.
6.3. Standard reference
Gefran products, described in this manual, are compliant to the European Directive 2014/30/EU.
They are tested according to the standard EN 61326-1 "Electrical equipment for measurement, control and laboratory use - EMC
requirements", Part 1 "general requirements and EN 61326-2-3 "Electrical equipment for measurement, control and laboratory use
- EMC requirements", Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for
transducers with integrated or remote signal conditioning.
Note
In accordance with IEC/EN 62061, IEC/EN 61508 and ISO/EN 13849, ILI series transducers also comply with EN 61326-3-1
"Electrical equipment for measurement, control, and laboratory use - immunity requirements for safety-related systems and for
equipment intended to perform safety-related functions (functional safety) - General industrial applications".
6.4. EMC and RoHS Requisites
Gefran Melt transducers and transmitters are built in conformity with the following EMC directives: EMC 2014/30/EU and RoHS
2011/65/EU
80618_MAN_IO-LINK IMPACT_12-2019_ENG
Unshielded
IL transducer
cable
Y splitter
Unshielded
IL transducer
cable
Y splitter
Machine
Press
Equipment
Rod /
Pressure intake
Ground
Machine
Press
Equipment
Rod /
Pressure intake
Ground
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ili0Ili1

Table of Contents