gefran ILI Series Original Operating Instructions page 18

Pressure sensors for high temperature io-link impact
Table of Contents

Advertisement

Event Code
Event Type
0x18A2
Notification
0x18A3
Notification
*In case of Block Parameterization (not Write Direct) this event happens each time one of any parameter is written; this behavior is
required for IO-Link certification test; do not care.
Table 8
Error codes
Error Code
0x8000
0x8011
0x8012
0x8022
0x8023
0x8030
0x8031
0x8032
0x8033
0x8034
0x8035
0x8036
0x8040
0x8041
• Predefined parameters – Profile specific parameters
Sub
Index
Object Name
Index
TeachIn
0x003A
0x00
Channel
TeachIn
0x003B
0x00
Result
0x01
State
0x02
FlagSP1TP1
0x03
FlagSP1TP2
0x04
FlagSP2TP1
0x05
FlagSP2TP2
0x003C
0x00
SSC1Param
0x01
SP1
0x02
SP2
0x003D
0x00
SSC1Config
0x01
Logic
0x02
Mode
18
Device Status Description
OK
event for Relay Threshold Changed, value confirmed
OK
event for Relay Threshold Changed, abort
Description
Device application error – no details
Index not available
Subindex not available
Service not available – Device control
Access denied
Parameter value out of range
Parameter value above limit
Parameter value below limit
Parameter length overrun
Parameter length underrun
Function not available
Function temporarily unavailable
Invalid parameter set
Inconsistent parameter set
Access
Data
Length
Type
U
M
S
-
R/W
R/W
1
UInt8
-
RO
RO
1
Boolean
-
RO
RO
4 bit
UInt4
-
RO
RO
1 bit
Boolean
-
RO
RO
1 bit
Boolean
-
RO
RO
1 bit
Boolean
-
RO
RO
1 bit
Boolean
RO
R/W
R/W
4
Record
RO
R/W
R/W
UInt16
2
RO
R/W
R/W
UInt16
2
RO
R/W
R/W
4
Record
RO
R/W
R/W
1
UInt8
RO
R/W
R/W
1
UInt8
VALUE (exam-
Value Range Gradient
ple)
0x00: SSC1
(default)
0...2
-
0x01: SSC1
0x02: SSC2
0: not OK
0...255
1...255: OK
0
0...15
-
See Table 11
0: SP1TP1 not
taught
0...255
-
1...255: SP1TP1
taught
0: SP1TP2 not
taught
0...255
-
1...255: SP1TP2
taught
0: SP2TP1 not
taught
0...255
-
1...255: SP2TP1
taught
0: SP2TP2 not
taught
0...255
-
1...255: SP2TP2
taught
According to MU
FS
0...FS
See Table 10
According to MU
0
0...FS
See Table 10
0x00: High
active
0...1
-
0x01: Low active
0x00:
Deactivated
0x01: single
0...3
-
point
0x02: window
0x03: two point
80618_MAN_IO-LINK IMPACT_12-2019_ENG
Note
Offset
Unit
Description
Defines the
-
-
channel to which
address teach-in
Show the result of
teach-in procedure
-
-
-
-
-
-
-
-
-
-
Defines the Switch-
points for Channel
1 (see par.7.6)
0
MU
From Specification:
SP1=SP "High"
SP2=SP "Low"
0
MU
Defines the config-
uration of Channel
1 (see par. 7.6)
-
-
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ili0Ili1