Connecting To Remote 14 Receptacle Rc14 - Miller Big Blue 400 Eco Pro CC Owner's Manual

Table of Contents

Advertisement

5-12. Connecting To Remote 14 Receptacle RC14

*The remaining sockets
are not used.
.
Accessories depend
on unit capabilities.
Notes
.
Not all models have contactor control. See description of front panel controls and
circuit diagram.
24 VOLTS AC
REMOTE
OUTPUT
CONTROL
OR
NEUTRAL
115 VOLTS AC
Rmt14_1 2010−04
Socket*
A
24 volts AC. Protected by supplementary protector.
B
Contact closure to A completes 24 volt AC contactor
control circuit.
C
Output to remote control:+10 volts DC in MIG mode;
0 to +10 volts DC in Stick or TIG mode.
D
Remote control circuit common.
E
DC input command signal: 0 to +10 volts from min.
to max. of remote control with Voltage/Amperage
Adjust control at maximum.
F
Current feedback: 1 volt per 100 amperes.
H
Voltage feedback: 1 volt per 10 arc volts.
K
Chassis common.
GND
G
Circuit common for 24 and 115 volt AC circuit.
115 volts, 10 amperes, 60 Hz AC. Protected by sup-
I
plementary protector.
Contact closure to I completes 115 volt AC contactor
J
control circuit.
Socket Information