2. Rack Installation Specifications
Rack Installation Requirements
Installing Three DEs for Each Node
This section describes the required (estimated) length of cable for configuring three DEs connected to each node
with 12 CEs installed.
Be sure to use a 1.1m cable to connect between the FE and CE#0.
A 3m or longer cable is required between the FE and CE#1 to CE#3 that are installed in the same rack.
A 10m or longer cable is required between the FE and CE#4 to CE#B in the expansion rack (or Expansion
Rack#0).
Table 16
Required Cable Length/Quantity (When Three DEs Are Connected per Node)
Cable length
Frontend cables (1.1m/3m)
Frontend cables (3m/3m)
Frontend cables (10m/10m) (*2)
*1: The required quantity varies depending on the number of CEs that are to be connected.
*2: This cable is required when racks are placed next to each other. Use a cable with the required length according to the rack arrangement
and the cabling.
Figure 40
Example of a Frontend Cable Connection (When Three DEs Are Connected for Each Node in a 19-
inch Rack [2000mm])
Base rack
CE#3
DE
DE
DE
CE#2
DE
DE
DE
CE#1
DE
DE
DE
CE#0
FE
PDU#7
PDU#6
PDU#5
PDU#4
PDU#1
PDU#3
PDU#0
PDU#2
: QSFP copper cable (for FE to CE#0 connections, 1.1m)
: QSFP copper cable (3m)
: QSFP active optical cable (10m)
Quantity (*1)
One set
Up to three sets
Up to eight sets
Expansion rack#0
Expansion rack#1
DE
DE
DE
DE
CE#A
DE
DE
CE#6
DE
DE
DE
DE
DE
CE#9
DE
DE
CE#5
DE
DE
DE
DE
CE#8
DE
DE
CE#4
DE
DE
DE
DE
CE#7
DE
PDU#7
PDU#6
PDU#5
PDU#4
PDU#1
PDU#3
PDU#1
PDU#0
PDU#2
PDU#0
56
Connection destination
For CE#0
For CE#1 to CE#3
For CE#4 to CE#B
Expansion rack#2
DE
DE
DE
CE#B
DE
PDU#7
PDU#6
PDU#5
PDU#4
PDU#3
PDU#1
PDU#2
PDU#0
: Management cable (for FE to CE#0 connections, 3m)